LSM Specifications
1-6 Revision P 95693
■LSM Specifications
Table 1- 1 lists the LSM specifications:
Table1-1. LSM Specifications
Description Specification
Power cab le US/Canada
100-120 VAC UL/CSA power cable
International
200 to 240 VAC HAR power cable
Input voltage range
Nominal voltage
100 or 240 VAC
100 to 254 VAC
Power configuration US/Canada:
100-120 VAC, single phase, 47 to 63 Hz, 20 a
Service, 3-wire
International:
200 to 240 VAC, single phase, 47 to 63 Hz, 10 a
Service 3-wire
Power consumption 200 W
Maximum heat output 683 Btu/hr
Temp era tur e
Operating
Storage
Shipping
15º to 32ºC (59º to 90ºF)
10º to 40ºC (50º to 104ºF)
-40º to 60ºC (-40º to 140ºF)
Relative Humidity
Operating
Storage
Shipping
20% to 80% (noncondensing)
10% to 95% (noncondensing)
10% to 95% (noncondensing)
Wet Bul b Max imum
Operating
Storage
Shipping
29.2º C (84.5ºF)
35º C (95ºF)
35º C (95ºF)
Altitude
Operating
Storage
Shipping
0 to 3.05 km (0 to 10,000 ft.)
0 to 3.05 km (0 to 10,000 ft.)
0 to 15.24 km (0 to 50,000 ft.)