Environmental Specifications
A-18 Revision P 95693
Environmental Specifications
The following tables list the different cartridge environmental specifications:
TableA-1. 9490 Cartridge Environmental Specifications
Operating Environment
Temperature 15.6º to 32.2ºC (60º to 90ºF)
Relative humidity 20% to 80%
Wet bulb temperature 25.6ºC (78ºF) maximum
Cartridge Storage Environment
Temperature 4.4º to 32.2ºC (40º to 90ºF)
Relative humidity 5% to 89%
Wet bulb temperature 26.7ºC (80ºF) maximum
TableA-2. SD-3 Cartridge Environmental Specifications
Operating Environment
Temperature 15º to 27ºC (59º to 81ºF)
Relative humidity 30% to 60%
Wet bulb temperature 25ºC (77ºF) maximum
Cartridge Storage Environment
Temperature 5º to 32ºC (41º to 90ºF)
Relative humidity 5%-80%
Wet bulb temperature 26ºC (80°F) maximum
TableA-3. DLT Cartridge Environmental Specifications
Operating Environment
Temperature 10º to 40ºC (50º to 104ºF)
Relative humidity 20% to 80% noncondensing
Wet bulb temperature 25ºC (77ºF) maximum
Cartridge Storage Environment
Temperature 16º to 32ºC (61º to 90ºF)
Relative humidity 20% to 80% noncondensing
Wet bulb temperature 26ºC (79ºF) maximum