2.3.8Reassembling the Cabinet

Follow the instructions in your system or expansion cabinet documentation. If necessary, be sure to:

Replace or close the top front panel

Replace or close the rear panel

Push the antitilt bar back into the cabinet

2.4Troubleshooting

If a GBIC is properly installed, the Device Active LED for the GBIC should be on and the Bypass LED should be off.

If the Device Active LED for a GBIC is flashing, replace the GBIC.

If a GBIC is installed and the Device Active LED for the GBIC is off and the Bypass LED is on, see TABLE 2-1.

TABLE 2-1Troubleshooting

Possible Cause

Solution

 

 

Module not properly inserted

Remove and reinsert the GBIC.

Diminished or missing signal from node

Plug the optical cable from the other device

 

into a known good GBIC.

Bad hub port

Move the GBIC to a known good port on

 

the hub.

Faulty GBIC

Replace the GBIC.

 

 

2-8Sun StorEdge FC-100 Hub Installation and Service Manual • September 1998

Page 30
Image 30
Sun Microsystems FC-100 service manual Troubleshooting, Reassembling the Cabinet