4.Verify that the selected NEM has returned the expected feedback. See “To Verify NEM Status” on page 17.
Using the ILOM CLI
1.Log in to the ILOM CLI of the active Chassis Monitoring Module.
2.For a list of components in your system, type: show /CH
3.To verify that the NEM Ready to Remove status has changed to Not Ready, type:
show /CH/component prepare_to_remove_status
The system returns:
prepare_to_remove_status = Not Ready
4.Verify that the selected NEM has returned the expected feedback. See “To Verify NEM Status” on page 17.
▼To Verify NEM Status
See TABLE
1.Check the following LEDs to verify that the NEM is ready for a
■Green OK LED goes to Standby.
2.Activate the NEM by pressing the Attention button, and the green OK LED goes to Slow blink.
■When all links to active blades have been made, the green OK LED goes to Solid On.
18 Sun StorageTek 4 Gb FC NEM