34

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

X

.

 

S

e

t

-

U

p

 

 

&

 

A

d

j

u

s

t

m

e

n

t

 

I X . S e t - U p & A d j u s t m e n t

35

Loosen the stem bolt (A) on the right fork using an 8mm Allen wrench. Do not remove the stem bolt. Simply loosen it enough to allow the teeth on the upper and lower splines to clear one another (B). With the stem bolt loosened, the caster fork should pivot freely. Place the wheelchair on the floor so that the two rear wheels and left caster contact the floor. Place some weight in the seat towards the rear to help stabilize the chair. Place a square or pocket level against the flat surface of the fork and pivot the fork until it is vertical (square). With the fork vertical, engage the teeth of the two splines to the closest mating position. Make certain that the teeth are properly engaged and not crossed. Shine a bright light behind the mating spline teeth and check for proper teeth engagement. Tighten the stem bolt to secure the spline mating position. The stem bolt should be tightened to 20 ft-lbs to ensure that it does not loosen during use.

Record the teeth engagement position of the splines on the right fork, and adjust the left fork in a similar fashion to the same position. Reassemble both casters, and re-check that they are square.

A

B

K. WHEEL LOCKS

 

NOTE– Use a torque setting of 100 in.-lbs when set-

 

ting-up wheel locks.

 

1. High-Mount Scissor Wheel Locks:

 

Loosen the screws (A) on the top of each clamp using

 

a 3/16 Allen wrench. Slide assembly toward rear wheel

A

until clamp embeds into tire to prevent wheel move-

 

ment when in locked position. Adjust angle position.

 

Tighten screws.

 

NOTE– Clamp and wheel lock may need to be rotated

B

to clear frame tubing.

 

2.High-Mount Push-to-Lock or Pull-to-Lock Wheel Locks

Loosen the screws (B) on the top of each clamp using a 3/16" Allen wrench. Slide clamp toward the rear wheel until the wheel lock is embedded into the tire to pre- vent wheel movement, when in the locked position. Adjust angle position. Tighten screws.

L. ANTI-TIP TUBES (OPTIONAL)

Sunrise Medical recommends anti-tip tubes for all

J. FOOTREST HEIGHT ADJUSTMENT

wheelchairs. Use torque setting of 88 in.-lbs. when installing anti-tip tubes.

NOTE– Use a torque setting of 100 in.-lbs. when adjusting footrest height.

To adjust the height of your footrest, loosen the two cap screws (C) on the footrest clamps. Slide the footrest up or down to the new desired height and tighten the two cap screws. Use a torque setting of 100 in-lbs (11.3 N-m). It is recommended that you maintain a minimum of 2.0 inches (5 cm) between the lowest point on the footrest and the floor. This will provide adequate clearance for uneven surfaces and prevent damage to your footrest.

C

1.Inserting Anti-tip Tubes Into Receiver

a.Press the rear anti-tip release lever on the anti-tip tube so that both release pins are drawn inside.

b.Insert the anti-tip tube (C) into the anti-tip receiver (D).

c.Turn the anti-tip tube down until release pin is through the receiver mounting hole.

d.Insert second anti-tip tube the same way.

2.Adjusting Anti-Tip Tube Wheel

The anti-tip wheels may have to be raised or lowered to achieve proper clearance of 1 1/2" to 2".

C

D

Press the anti-tip wheel release button so that both release pins are drawn inside. Raise or lower to one of the three predrilled holes. Release button. Adjust the second anti-tip tube wheel the same way. Both wheels should be exactly the same height.