SUPERSERVER 6014L-T User's Manual

2-4 Installing the System into a Rack

This section provides information on installing the SuperServer 6014L-T into a rack unit. If the system has already been mounted into a rack, you can skip ahead to Sec- tions 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. The following is a guideline for installing the unit into a rack with the rack rails provided with the system. You should also refer to the installation instructions that came with the rack unit you are using.

Identifying the Sections of the Rack Rails

You should have received two rack rail assemblies with the SuperServer 6014L-

T.Each of these assemblies consist of two sections: an inner fi xed chassis rail that secures to the unit (A) and an outer fi xed rack rail (B) that secures to the rail brackets. A sliding rail guide sandwiched between the two should remain attached to the fi xed rack rail (see Figure 2-1). The A and B rails must be detached from each other to install.

To remove the fi xed chassis rail (A), pull it out as far as possible - you should hear a "click" sound as a locking tab emerges from inside the rail assembly and locks the inner rail. Then depress the locking tab to pull the inner rail completely out. Do this for both the left and right side rack rail assemblies.

Figure 2-1. Identifying the Sections of the Rack Rails

Mounting Holes

B

Locking Tab

A

2-4

Page 22
Image 22
SUPER MICRO Computer 6014L-T user manual Installing the System into a Rack, Identifying the Sections of the Rack Rails