LIGHTING INSTRUCTIONS – MILLIVOLT

LIGHTING INSTRUCTIONS – MILLIVOLT

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Extinguish any open flame.

Open windows.

Do not light any appliance.

Do not touch any electrical switches.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone.

If your gas supplier cannot be reached, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or an explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this page.

2.Access left side louver.

3.Turn remote wall switch to “OFF.”

4.Verify main line shut-off valve is open.

5.Push in gas control knob slightly and turn clockwise

FOR YOUR SAFETY READ BEFORE LIGHTING to “OFF.”

Gas Control Knob

Flame Adjustment Knob

 

 

 

PIL

SIT Millivolt

 

 

Valve

 

 

OT

 

T

O N

 

 

it

 

TH

L

 

O

 

 

 

I

 

 

 

P

FFO

 

 

 

 

TP

 

 

 

 

 

 

TPTH

EA

Piezo Ignitor

 

 

O

 

 

N

 

 

L

 

P

O

 

IH

 

LI

 

O

 

FFO T

 

 

Honeywell

 

 

Millivolt Valve

 

 

Gas Control Knob

 

Spark Ignitor

Note: Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force.

6.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above on this page. If you do not smell gas, go to the next step.

7.Push in gas control knob slightly and turn counterclockwise

LIGHTING INSTRUCTIONS to “PILOT.”

8.Push in control knob all the way and hold in. Immediately light the pilot by triggering the spark ignitor (pushing red button) until pilot lights. Continue to hold the control knob in for about 1 ¹⁄₂ minutes after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

Thermopile

If knob does not pop up when released, stop and

immediately call your

Thermocouple

service technician or gas

 

supplier.

Ignitor

 

If pilot will not stay lit after

several tries, turn the control knob to “OFF” and call your service technician or gas supplier.

9.Turn gas control knob counterclockwise TO TURN OFF GAS TO APPLIANCE to “ON.”

10.Close the side louver.

Note: If the gas valve is turned directly from the “ON” to “OFF” position, the valve will latch in the “OFF” position for 60 seconds.

TO TURN OFF GAS TO APPLIANCE

1.

Turn remote wall switch “OFF.” The pilot will remain lit for

4.

Depress gas control knob slightly and turn clockwise

 

normal service.

 

to “OFF.” Do not force.

2.

For complete shutdown, turn remote wall switch to “OFF.”

5.

Close the side louver.

3.Access the left side louver.