Danaher Motion Superior Electric

3.3.1 Motor Connections

All motor connections are made via the 6-terminal strip (J1). Terminal assignments are given below. Motor connections are shown in Figure 3.3.

J1 Pin Assignment

1M1 (Phase A+)

2M3 (Phase A-)

3M4 (Phase B+)

4M5 (Phase B-)

Motor phase A is M1 and M3 and motor phase B is M4 and M5. The motor frame must be grounded.

Cabling from the drive to the motor should be done with a shielded, twisted pair cable. As a guideline, the wires for each motor phase should be twisted about six times per foot.

Danaher Motion offers the following motor cable configurations. These cables have unterminated leads on both ends.

Length

Part Number

10 ft (3 m)

216022-031

25 ft (7.6 m)

216022-032

50 ft (15.2 m)

216022-033

75 ft (22.8 m)

216022-034

Figure 3.3 shows the possible motor wiring configurations.

SS2000MD4

10

400030-043 Rev G

Page 10
Image 10