Danaher Motion Superior Electric
4.5CURRENT SETTINGS
The proper current setting for each motor is shown on the individual torque vs. speed curves. Use this current level to obtain the torque shown. Switches 1 through 7 select the current level. Select the desired operating current by setting the appropriate switch to position 1 (ON). The OFF position is labeled "0". Only one switch should be ON. If two or more switches are ON, the one that selects the highest current level is the active switch. The switch settings are:
| Current |
Position | (amperes) |
None | 0.5 |
10.75
21.0
31.5
42.0
52.5
63.0
73.5
4.6STEP RESOLUTION
The number of pulses per revolution is selected using position 8 of the switch described in Section 4.5. The following chart shows the correct switch setting for each available step resolution.
Switch | Step | Pulses Per |
|
Position 8 | Resolution | Revolution |
|
|
|
|
|
0 (off) | 200 |
| |
1 (on) | 400 |
| |
|
|
|
|
|
|
|
|
|
| MOTOR CURRENT & | |
|
| STEP RESOLUTION | |
|
| SWITCHES |
J2
J1
Figure 4.1 Switches For Setting Current Level and Step Resolution
SS2000MD4 | 15 |