Danaher Motion Superior Electric

4.7.4 Timing Requirements

PULSE

 

Max. Frequency

20 kHz

Max. Rise and

 

Fall Times

1 microsecond

Min. Pulse

 

Width

25 microseconds

Other Signals

 

Response Time

25 microseconds

OPTO IN

PULSE DRIVE

OPTO IN

PULSE DRIVE

OPTO IN

PULSE DRIVE

OPTO IN

PULSE DRIVE

12 VDC, 16 mA PER SIGNAL

560 ohms

CONTROL SIGNAL

1/4 watt

CONTROL LOGIC COMMON

4.5 - 6.0 VDC, 16 mA PER SIGNAL

CONTROL SIGNAL

CONTROL LOGIC COMMON

4.5 - 6.0 VDC, 16 mA PER SIGNAL

TTL

CONTROL SIGNAL

7406

5V

SWITCH

OPTO 5V GND

Figure 4.2 Suggested Methods For Control Interface

4.8INDICATOR LIGHTS

"FAULT" LED, Red

Lights to indicate over current condition. This condition is caused by motor wiring errors or a ground fault.

Recovery from over current condition requires removing and then reapplying the power.

SS2000MD4

17

400030-043 Rev G

Page 17
Image 17
Superior SS2000MD4 installation instructions Timing Requirements, Indicator Lights