Code

Error Messages

Potential Cause(s)

 

 

 

 

 

 

+3008

Invalid Calibration State

An invalid sequence of calibration commands was received.

 

 

For example, a CALn:CONF:VOLT command followed by a

 

 

CALn:VAL:CURR command.

 

 

 

+3009

Invalid Calibration Channel

An invalid channel number, n, was requested in the

 

 

CALn:CONF or CALn:VAL commands.

 

 

 

+3010

Calibration aborted

A command, other than one of the CALibration commands, was

 

 

received during the calibration process.

 

 

 

+3011

Checksum error on Calibration

Calibration constants in RAM are corrupted. Recalibration is

 

Memory

needed.

 

 

 

+3012

Channel cannot be programmed to

An attempt to set the channel output mode when the P/J jumper

 

this mode, check jumpers

is set to Jumper selectable and the mode is set by the V/I

 

 

jumper.

 

 

 

+3013

Waiting for Trigger

An attempt to change a channel output value or mode was

 

 

made after the trigger system in the wait-for-trigger state.

 

 

 

+3014

Illegal while initiated

An attempt to program a channel was made when the channel

 

 

is in the wait-for-trigger state.

 

 

 

+3015

Non-volatile memory write failed

Indicates a hardware failure in non-volatile memory.

 

 

 

 

 

 

Appendix C

HP E1418A Error Messages 152

Page 152
Image 152
HP manual Appendix C HP E1418A Error Messages