TRIGger

TRIGger:SOURce

TRIGger:SOURce sets the trigger source for the module.

Parameters

Parameter

Parameter

Range of

Default

Name

Type

Values

 

 

 

 

 

<source>

discrete

TTLT0, TTLT1, TTLT2, TTLT3, TTLT4,

none

 

 

TTLT5, TTLT6, TTLT7, BUS, HOLD,

 

 

 

IMM, or EXT

 

 

 

 

 

Comments ∙ The <source> parameter defines the following trigger conditions:

<source>

Trigger

TTLT0–TTLT7

Sets the trigger source to one of the VXIbus backplane trigger lines.

 

 

BUS or HOLD

Sets software trigger. A *TRG, TRIG:IMM, or GET will trigger the output.

 

 

IMMediate

Places the trigger system in the wait-for-trigger state and then triggers the output.

 

 

EXTernal

Sets the trigger source to the EXTernal trigger line on the terminal module.

∙If this command is received when the module is in the wait-for-trigger state, an error is generated.

∙This command set the source for the trigger in to the module. The module can also output a trigger on the VXIbus TTLTrg lines using the OUTPut:TTLTrgn command.

∙Triggering is described in more detail on page 54.

∙Related Commands: TRIGger:SOURce?

∙*RST Condition: Trigger source set to HOLD.

TRIGger:SOURce?

TRIGger:SOURce? queries the trigger source for the module.

Parameters Returns: string.

Comments ∙ The query returns one of the following unquoted strings:

String

Trigger Source

TTLTn

VXIbus backplane trigger line n

 

 

BUS

Software trigger

 

 

HOLD

Trigger hold (reset state)

 

 

IMM

Immediate trigger

 

 

EXT

External trigger

Chapter 3

HP E1418A SCPI Command Reference 105