TRIGger

TRIGger

 

The TRIGger subsystem controls when and how the outputs are enabled.

 

Other commands, designed for use with the TRIGger subsystem are ABORt

 

and INITiate[:IMMediate].

Subsystem Syntax

TRIGger

 

[:IMMediate]

 

:SOURce <source>

 

:SOURce?

TRIGger[:IMMediate]

TRIGger[:IMMediate] triggers all channels waiting for trigger when the trigger source has been set to either BUS or HOLD.

Parameters None.

Comments To use this command to trigger outputs, the trigger source must be set to either BUS or HOLD. An error is generated if other trigger sources are set.

If this command is received and the module is not in the wait-for-trigger state, an error is generated.

Triggering is described in more detail on page 54.

Related Commands: TRIGger:SOURce,

SOURcen:VOLTage[:LEVel][:IMMediate]:TRIGgered[:AMPLitude], SOURcen:CURRent[:LEVel][:IMMediate]:TRIGgered[:AMPLitude]

104 HP E1418A SCPI Command Reference

Chapter 3