Superior VFGL-24MSP-4 SERIES* dimensions Table Of Contents, General Information, Inventory

Models: VFGL-24MSN-4 SERIES* VFGL-24VSP-4 SERIES VFGL-18VSN-4 SERIES VFGL-28VSN-4 SERIES VFGL-28MSP-4 SERIES* VFGL-18VSP-4 SERIES VFGL-28MSN-4 SERIES* VFGL-24VSN-4 SERIES VFGL-24MSP-4 SERIES* VFGL-18MSN-4 SERIES* VFGL-18MSP-4 SERIES* VFGL-28VSP-4 SERIES

1 20
Download 20 pages 32.39 Kb
Page 2
Image 2
TABLE OF CONTENTS

2

TABLE OF CONTENTS

 

 

General Information

page

2

Inventory

page

2

Tools Required

page

2

Important Safety Information

page

2

Codes

page

3

Combustion and Ventilation Air

page

3

Preinstallation

page

4

Clearances

page

4

Installation

page

6

Gas Pressure Check

page

7

Flame Appearance

page

8

Operation

page

8

Cleaning and Servicing

page

8

Replacement Parts

page

8

Optional Equipment/Accessories

page

9

Heater Specification Chart

page 10

Heater Technical Detail Chart

page 10

Troubleshooting Guide

page 11

Operating Instructions – Manual

page 12

Operating Instructions – Millivolt ....

page 14

Replacement Parts List

page 16

GENERAL INFORMATION

These Unvented Gas Log Room Heaters incor- porate unitized ceramic fiber logs which glow realistically when the heater is operating.

The log sets covered in this document are manually controlled heater rated units. These units are equipped with either a standard manual gas valve or a millivolt gas valve. The control knob is set to the desired position, which main- tains a continuous gas burning rate.

A spark ignition system (piezo) allows the gas pilot to be lit without the use of matches or batteries and permits operation of the heater during a power outage.

These heaters are fitted with a specially de- signed pilot utilizing an oxygen depletion sen- sor (ODS) which responds to the amount of oxygen available in the room and shuts the heater off before the oxygen level drops below 18%. The pilot can be relit only when fresh air is available. Refer to the Combustion and Ven- tilation Air section.

WARNING: THIS APPLIANCE IS FOR IN- STALLATION ONLY IN A SOLID FUEL BURNING FIREPLACE WITH A WORKING FLUE OR AN APPROVED VENTLESS FIRE- BOX ENCLOSURE.

Minimum Fireplace (Firebox) Size

Log Set

Height

Depth

Width

 

 

 

 

18" Models

16"

14"

20" Front

 

 

 

19" Rear

 

 

 

 

24" Models

16"

14"

35" Front

 

 

 

27" Rear

 

 

 

 

28" Models

16"

14"

38" Front

 

 

 

30" Rear

Table 1

Do not install these Unvented Gas Log Room Heaters in a bedroom or a bathroom as all units exceed maximum allowable BTU/hr in- put of 10,000.

Check the inventory list to be sure that you have all the necessary parts in usable condition. Also check for concealed damage.

Inventory

Unvented gas log room heater Two (2) screws

Bag of decorative volcanic rock Ceramic fiber log set

Installation and Operating Instructions

Tools and Supplies Normally Required

External regulator (Propane models only) Manual shut-off valve

Sediment trap

Piping complying with local codes Pipe compound

Pipe wrench Tee joint Screwdriver

IMPORTANT SAFETY INFORMATION

INSTALLER: PLEASE LEAVE THESE INSTRUC- TIONS WITH THE OWNER.

OWNER: PLEASE RETAIN THESE INSTRUC- TION FOR FUTURE REFERENCE

IMPORTANT: READ THESE INSTALLATION IN- STRUCTIONS CAREFULLY BEFORE INSTALL- ING OR TRYING TO OPERATE THIS HEATER.

WARNING: FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING IN- STRUCTIONS PROVIDED IN THIS DOCU- MENT WILL RESULT IN AN IMPROPERLY INSTALLED AND OPERATING APPLI- ANCE, VOIDING ITS WARRANTY. ANY CHANGE TO THIS APPLIANCE AND/OR ITS OPERATING CONTROLS IS DANGER- OUS. IMPROPER INSTALLATION OR USE OF THIS APPLIANCE CAN CAUSE SERI- OUS INJURY OR DEATH FROM FIRE, BURNS, EXPLOSION OF CARBON MON- OXIDE POISONING.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nau- sea. If you have these signs, obtain fresh air immediately. Turn off the gas supply to the appliance and have it serviced by a qualified professional, as it may not be operating correctly.

Due to high temperatures, the heater should be located out of traffic and away from furniture and draperies.

Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition.

Young children should be carefully super- vised when they are in the same room with the heater.

Do not place clothing or other flammable material on or near the heater.

Any safety screen or guard removed for servicing the heater must be replaced prior to operating the heater.

Installation and repair should be done by a qualified service person. The heater should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is important that control compartments, burn- ers and circulating air passageways of the heater be kept clean.

Allow the heater to cool before servicing. Always shut off the gas to the heater while performing service work.

Do not install the heater in a bedroom or bathroom.

Page 2