Depth Sounder
Setting Units
The depth sounder can display depth in either standard or metric units.
Perform the following steps to change the display units:
1.Simultaneously press the up and down buttons.
Either the FT or M units indicator display text will flash.
THEN...
2.To set feet units, press the up button.
The FT indicator display text will flash for five seconds and return to normal mode display with feet as the current units.
OR...
3.To set Meter units, press the down button.
The M indicator display text will flash for five seconds and return to normal mode display with Meters as the current units.
NOTE: When power is applied or removed and reapplied, the units display defaults to feet units.
Setting Deep Alarm
The deep alarm function can be set for depths ranging from 3 feet (1.0 Meter) to 200 feet (60.9 Meters). An alarm triggers when the water depth is greater than the set value.
Setting Deep Alarm (continued)
To set the Deep Alarm, perform the following:
1.Press the down button. The current deep alarm depth setting will display.
2.Press the up or down button to increase or decrease respectively the deep alarm depth value.
Pressing either button once will change the depth value in
3.After setting the depth value, the alarm and down arrow icons will blink for five seconds then the display will return to normal operating mode with the alarm and down arrow icons displayed.
When triggered, an audible alarm sounds for ten seconds while flashing the warning LED, alarm and down icons on the display. After ten seconds, the audible alarm mutes but the LED and display icons continue to flash.
NOTE: When power is removed from the instrument, all depth settings are returned to “000”.
Setting Shallow Alarm
The shallow alarm function can be set for depths ranging from 3 feet (1.0 Meter) to 200 feet (60.9 Meters). An alarm triggers when the water depth is less than the set value.
To set the Shallow alarm, perform the following:
1.Press the up button. The current shallow alarm depth setting will display.
2.Press the up or down button to increase or decrease respectively the shallow alarm depth value.
Pressing either button once will change the depth value in
3.After setting the depth value, the alarm and up arrow icons will blink for five seconds then the display will return to normal operating mode with the alarm and up arrow icons displayed.
When triggered, an audible alarm sounds for ten seconds while flashing the warning LED, alarm and up icons on the display. After ten seconds, the audible alarm mutes but the LED and display icons continue to flash.
NOTE: When power is removed from the instrument, all depth settings are returned to “000”.
— 34 | © 2006 Skier’s Choice, Inc. |