Plan Vent System

Plan Vent System

Choose your exhaust installation type

Recommended exhaust installations

Typical installations vent the dryer from the rear of the dryer. Other installations are possible.

 

B

 

C

 

D

A

E

 

F

 

G

 

H

A. Dryer

E. Clamps

B. Elbow

F. Rigid metal or flexible metal vent

C. Wall

G. Vent length necessary to connect elbows

D. Exhaust hood

H. Exhaust outlet

Optional exhaust installations

This dryer can be converted to exhaust out the right side, left side, or through the bottom. Contact your local dealer to have the dryer converted.

Choose your exhaust installation typeWARNING

Fire Hazard

Cover unused exhaust holes with one of the following kits:

279818 (white)

279915 (black diamond)

280102 (pacific blue)

280103 (champagne)

280189 (barolo)

Contact your local dealer.

Failure to follow these instructions can result in death, fire, electrical shock, or serious injury.

ABC

A. Standard rear offset exhaust installation B. Left or right side exhaust installation

C. Bottom exhaust installation (not an option with pedestal installations)

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions.

AB

A. Over-the-top installation (also available with one offset elbow) B. Periscope installation

NOTE: The following kits for close clearance alternate installations are available for purchase. For further information, please call 1-800-4-MY-HOME®(1-800-469-4663).

Over-the-Top Installation: Part Number 26-49900

Periscope Installation (For use with dryer vent to wall vent mismatch):

Part Number 26-49901 - Less than 5" (12.7 cm) mismatch

Part Number 26-49908 - 5" (12.7 cm) to 18" (45.72 cm) mismatch

Part Number 26-49904 - 18" (45.72 cm) to 29" (73.66 cm) mismatch

Part Number 26-49905 - 29" (73.66 cm) to 50" (127 cm) mismatch

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

Determine vent path

Select the route that will provide the straightest and most direct path outdoors.

Plan the installation to use the fewest number of elbows and turns.

When using elbows or making turns, allow as much room as possible.

Bend vent gradually to avoid kinking.

Use the fewest 90° turns possible.