•Depth accuracy: 0.3 m/1 ft
Operating conditions:
•Normal altitude range: 0 to 3,000 m/10,000 ft above sea level
•Operating temperature: 0°C to 40°C/32°F to 104°F
•Storage temperature:
It is recommended that the instrument be stored in a dry place at room temperature.
NOTE | Do not leave the dive computer in direct sunlight! |
Tissue calculation model:
•Suunto Deep Stop RGBM algorithm (developed by Suunto and Bruce R. Wienke, BSc, MSc, PhD)
•9 tissue compartments
•Tissue compartment halftimes: 2.5, 5, 10, 20, 40, 80, 120, 240 and 480 minutes (on gassing). The off gassing halftimes are slowed down
•Reduced gradient (variable) "M" values based on diving habit and dive violations. The "M" values are tracked up to 100 hours after a dive
•The EAN and oxygen exposure calculations are based on recommendations by R.W. Hamilton, PhD and currently accepted exposure time limit tables and principles
Battery:
•One 3 V lithium battery: CR 2450
•Battery storage time (shelf life): Up to three years
•Replacement: Every three years, or more often depending on dive activity
•Life expectancy at 20°C/68°F:
• 0 dives/y - 3 years
101