Tanita BC-418MA Transmission Data, Output data, Switching to Remote Mode, Control Commands

Models: BC-418MA

1 21
Download 21 pages 20.44 Kb
Page 15
Image 15

GB

Output (Fat Monitor Mode) Format

WTransmission Data

mCAUTION The receiving PC must be ready to accept output data immediately after measurement is completed.

Output data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte Length

 

 

First byte

K: unit of weight kg

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

L: unit of weight lb

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Header

 

S: stability of load (weight output)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D: instability of load (weight output)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Second byte

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

I : overload status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

---: negative weight output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

xxx.x

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

Output data format

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

¥

Terminal data are CR (ASCII format: 0DH), LF (ASCII format: 0AH).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

¥

Measurement data will be sent in the format shown to the right:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x

x

x

x

x

.

x

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote Mode

All types of data may be entered by connecting the BF-350 to a PC and switching to Remote mode.

WSwitching to Remote Mode

 

kg

1. When the unit is switched off, press the [

]

P T

 

and [ ] keys simultaneously.

 

MALE

STABILIZED

mNote The default setting is off.

 

FEMALE

cm / ft.in

 

ATHLETIC

AGE

 

STEP ON

% FAT

 

 

WControl Commands

When in Remote mode, the body fat analyzer may be operated remotely by sending control commands from a host.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

commands

 

U

?

CR

 

 

 

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

U? : Confirm current setting

 

U

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U0: Use cm/kg mode

U

 

CR

 

 

 

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U1: Use in/lb mode

 

 

CR

 

 

 

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R? : Confirm current setting

commands

 

CR

 

 

 

LF

 

 

 

 

 

 

 

 

 

 

R

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R0: Select equation for Westerners

R

 

CR

 

 

 

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R1: Select equation for Orientals

 

 

CR

 

 

 

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D? : Confirm current setting

 

 

CR

 

 

 

LF

 

 

 

 

 

 

 

 

 

 

 

D

0

X

 

X

 

 

 

X

.

X

 

 

 

 

D0

: Set clothing weight (5-byte fixed length)

 

 

 

 

 

 

CR

LF

 

 

D

1 X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1

: Set gender male = 1 female = 2

commands

 

CR

LF

 

 

 

 

 

 

 

 

 

 

D

2

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D2

: Set body type standard = 0 athlete = 2

D

 

 

CR

 

 

LF

 

 

 

 

 

 

 

 

 

 

 

D

3

X

 

X

 

 

 

X

X

X

 

 

 

 

D3

: Set height (5-byte fixed length)

 

 

 

 

 

 

CR

 

LF

 

 

 

D

4

X

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D4

: Set age (2-byte fixed length)

 

 

 

 

 

CR

 

 

 

LF

 

 

 

 

 

D

6 X X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D6

: Set Target BF (2-byte fixed length)

 

 

CR

 

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

commands

 

G

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G1: Start measuring body fat

CR

 

 

 

LF

 

 

 

 

 

 

 

 

 

G

 

G

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G2: Measure weight only

CR

 

 

 

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Special

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

commands

 

CHR$(01FH)

 

 

 

 

CR

 

 

 

LF

 

 

 

 

 

CHR$(01FH): Reset settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*All fixed-length data right aligned. Enter 0 for blanks.

GB

 

kg

P T

 

MALE

STABILIZED

FEMALE

cm / ft.in

ATHLETIC

AGE

STEP ON

% FAT

 

kg

P T

 

MALE

STABILIZED

FEMALE

cm / ft.in

ATHLETIC

AGE

STEP ON

% FAT

 

kg

P T

 

MALE

STABILIZED

FEMALE

cm / ft.in

ATHLETIC

AGE

STEP ON

% FAT

2.Press [0], [8].

3.Switch Remote mode on and off by pressing [1]

or [0].

[1]: Enables Remote mode

[0]: Disables Remote mode

4.Press [ ] to confirm.

Only "r S" will appear (standby screen).

mTo switch off Remote mode, start Note from the beginning again and

select "OFF" at Step 3.

WError Codes

If an error occurs, the body composition analyzer will send an error code to the host.

 

 

 

 

 

 

 

 

 

E

0

0

CR

 

LF

 

E00

: Attempted to start measuring without completing settings

E

0

1

 

 

 

 

E01

: Error in calculating body fat percentage

CR

LF

E

X

X

 

 

 

 

EXX :other error ’ body fat analyzer switches off

CR

LF

 

 

 

 

 

 

 

 

 

*See p.26 "7. Troubleshooting" for details of errors.

30

31

Page 15
Image 15
Tanita BC-418MA instruction manual Transmission Data, Output data, Switching to Remote Mode, Control Commands, Error Codes