Troubleshooting

If you are concerned that the scale may not be functioning correctly, please check the following points before requesting repairs.

Specifications

Model

BD-815U

Capacity

33 lb (15000g)

GB Problem

Nothing is displayed

when the key is s pressed.

Check points

Have the batteries been removed, or has the AC adapter been unplugged?

Are the batteries running low?

Is anything stuck to the terminals of the batter- ies?

Page

P.12

d (division)

0.1oz(0-12lb)

0.2oz(12-33lb)

2g (0-6000g)

5g (6000-15000g)

 

 

 

 

Maximum tare

4lb (2000g)

 

 

 

 

Extended calibration (uncertified)

0.05oz (1g)

 

 

 

 

Display panel

Backlit LCD

 

(Backlight is on only when the AC adapter is used)

 

GB

 

is displayed. s

• The batteries are running out. Please replace

P.12

 

 

them immediately or use the AC adapter.

 

 

After the power is

 

 

 

 

• Is any pressure being applied to the baby basket

 

turned on,

 

 

s

P.14

 

 

 

 

 

 

 

when the power is turned on?

is displayed, and an

 

• Has basket been removed?

 

alarm sounds.

 

 

 

 

 

is shown

 

 

 

 

 

 

• The maximum measurable weight capacity for

 

 

 

 

 

during measure- s

P.7

the scale (33lb / 15 kg) is exceeded.

 

 

 

 

 

 

 

ment.

External interface

RS-232C (D-sub 9-pin female connector),

unidirectional output

 

 

 

Power supply

Input: AC 120 V (60 Hz) Output: DC 9 V / 200mA

 

 

Regular voltage

DC 6 V (using the batteries)

DC 9 V (using the AC adapter)

 

 

 

Power consumption

0.12 W or less (using the batteries)

0.35 W or less (using the AC adapter)

 

 

 

Consumption current

20mA (using the batteries)

38mA (using the AC adapter)

 

 

 

Operating temperature

41˚F - 95˚F (5˚C - 35˚C)

 

 

Storage temperature

14˚F - 122˚F (-10˚C - 50˚C)

 

 

Overall dimensions

D16.1 W23.6 H6.2in (D409 W600 H157mm)

 

 

Main unit mass

Approx. 10.1lb(4.6kg)

 

 

Main material

ABS resin

 

 

Made in

Japan

26

27

Page 14
Image 14
Tanita BD-815U instruction manual GB Problem, Check points