TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications

5. Return Command Detail

5-1. TIME DATA

When the Time mode is set to other than “OFF” with TIME DATA SEND SELECT command [3F], controlled device outputs the time data in specified form by TIME DATA SEND SELECT command [3F].

 

Command

88

 

 

 

 

 

Data

 

8 bytes

 

 

 

 

 

 

 

 

 

 

 

 

Description

 

Remarks

 

 

 

Data 1

Tens digit of minutes

 

 

 

 

 

Data 2

Units digit of minutes

 

 

 

 

 

Data 3

Thousands digit of minutes

 

 

 

 

 

Data 4

Hundreds digit of minutes

 

 

 

 

 

Data 5

Tens digit of seconds

 

 

 

 

 

Data 6

Units digit of seconds

 

 

 

 

 

Data 7

Tens digit of frames

 

 

 

 

 

Data 8

Units digit of frames

 

 

 

 

5-2. INFORMATION RETURN

 

 

 

 

 

Transmitted in response to an INFORMATION REQUEST command [0F].

 

Returns the software version of the controlled device.

 

 

 

Command

8F

 

 

 

Data

 

4 bytes

 

 

 

Request command

INFORMATION REQUEST [0F]

 

 

 

 

 

 

 

 

Data 1

Tens digit of software version

 

Sample data for Data 1 - Data 4

 

Data 2

Units digit of software version

 

0100

Version 1.00

 

Data 3

1st decimal digit of software version

 

 

 

 

Data 4

Hundreds digit of software version

 

 

 

5-3. AUTO CUE LEVEL RETURN

Transmitted in response to an AUTO CUE LEVEL PRESET command [20] with the request data ([FF]) to show the currently set Auto Cue level.

Command

A0

 

Data

 

2 bytes

 

Request command AUTO CUE LEVEL PRESET [20]

 

 

 

 

 

Data 1

 

Data 2

Description

Remarks

0

 

0

-24dB

Auto Cue detect level is set to –24dB

0

 

1

-30dB

Auto Cue detect level is set to –30dB

0

 

2

-36dB

Auto Cue detect level is set to –36dB

0

 

3

-42dB

Auto Cue detect level is set to –42dB

0

 

4

-48dB

Auto Cue detect level is set to –48dB

0

 

5

-54dB

Auto Cue detect level is set to –54dB

0

 

6

-60dB

Auto Cue detect level is set to –60dB

0

 

7

-66dB

Auto Cue detect level is set to –66dB

0

 

8

-72dB

Auto Cue detect level is set to –72dB

18

TEAC Corporation

Page 18
Image 18