Tascam CD-01U Time Data Send Select, Play Mode Select, Play Mose Sense, Mecha Status Sense

Models: CD-01U

1 26
Download 26 pages 28.73 Kb
Page 15
Image 15

TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications

4-23. TIME DATA SEND SELECT

Sets the Time mode of the time data that is sent out from the controlled device automatically (without any request command).

When this command is transmitted with request data [FF], the controlled device returns the TIME DATA SEND SELECT RETURN command [BF].

When specified data includes “Without Frame” information, frame information will not shown on the

display of the controlled device.

 

 

Command

3F

 

 

Data

 

2 bytes

 

 

Return

TIME DATA SEND SELECT RETURN [BF]

 

 

 

 

 

 

 

Data 1

 

Data 2

Description

Remarks

 

0

 

0

Off

Time data (TIME DATA [88]) will not be sent

 

 

 

 

 

out from the controlled device automatically

 

0

 

1

Elapsed Time

With frame data

 

0

 

2

Remain Time

With frame data

 

0

 

4

Total Remain Time

With frame data

 

1

 

1

Elapsed Time

Without frame data

 

1

 

2

Remain Time

Without frame data

 

1

 

4

Total Remain Time

Without frame data

 

F

 

F

Time Data Send status request

Requests the Output Time Data status

·If the specified data is other than described above, the controlled device sends ILLEGAL [F2].

4-24. PLAY MODE SELECT

Sets the Play mode.

The status of the PLAY mode can be requested using the PLAY MODE SENSE command [4E].

Command

4D

 

Data

 

2 bytes

 

Return

None

 

 

 

 

 

 

Data 1

 

Data 2

Description

Remarks

0

 

0

Normal Play

Sets the Play Mode to normal (continuous) play mode

0

 

1

Single Play

Sets the Play Mode to single play mode

0

 

2

Program Play

Sets the Play Mode to program play mode

0

 

3

Random Play

Sets the Play Mode to random play mode

·If the specified data is other than described above, the controlled device sends ILLEGAL [F2].

4-25. PLAY MOSE SENSE

Requests the status of the Play mode.

The contents of the reply are described in the PLAY MODE RETURN command.

Command

4E

Data

None

Return

PLAY MODE RETURN [CE]

4-26. MECHA STATUS SENSE

Requests the status of the mechanism.

The contents of the reply are described in the MECHA STATUS RETURN command.

Command

50

Data

None

Return

MECHA STATSU RETURN [D0]

15

TEAC Corporation

Page 15
Image 15
Tascam CD-01U specifications Time Data Send Select, Play Mode Select, Play Mose Sense, Mecha Status Sense