TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications

4-14. FADE IN/OUT TIME PRESET

Sets the fade in and out time from 1 to 10 seconds in 1 second steps.

When this command is transmitted with request data ([00FF] or [01FF]), the controlled device returns the FADE IN/OUT TIME RETURN command [AE].

The FADE mode is turned on and off using the FADE IN/OUT SELECT command [3E].

 

Command

2E

 

 

 

Data

4 bytes

 

 

 

Return

FADE IN/OUT TIME RETURN [AE]

 

 

 

 

 

 

 

Data 1

 

Data 2

Data 3

Data 4

Remarks

0

 

0

Tens digit of Fade In time

Units digit of Fade In time

Sets the Fade In time

0

 

0

F

F

Requests the Fade In

 

 

 

 

 

time

0

 

1

Tens digit of Fade Out time

Units digit of Fade Out time

Sets the fade Out time

0

 

1

F

F

Requests the Fade

 

 

 

 

 

Out time

·If the specified data is other than described above, the controlled device sends ILLEGAL [F2].

·If the specified data is out of range, the controlled device sends ILLEGAL [F2].

4-15. AUTO CUE SELECT

Turns the Auto Cue function on and off.

When this command is transmitted with request data ([FF]), the controlled device returns the AUTO CUE SELECT RETURN command [B0].

The Auto Cue level is set using the AUTO CUE LEVEL PRESET command [20].

Command

30

 

Data

 

2 bytes

 

Return

AUTO CUE SELECT RETURN [B0]

 

 

 

 

 

Data 1

 

Data 2

Description

Remarks

0

 

0

AUTO CUE MODE OFF

Turns the Auto Cue function off

0

 

1

AUTO CUE MODE ON

Turns the Auto Cue function on

F

 

F

Auto Cue mode status request

Requests the Auto Cue mode status

·If the specified data is other than described above, the controlled device sends ILLEGAL [F2].

4-16. EOM TRACK TIME SELECT

Sets the EOM (End of message) time.

When this command is transmitted with request data ([FF]), the controlled device returns the EOM TRACK TIME RETURN command [B2].

The EOM time should be set to 00, 05, 10, 15, 20, 25, 30, or 35.

Command

32

 

Data

 

2 bytes

 

Return

EOM TRACK TIME RETURN [B2]

 

 

 

 

 

Data 1

 

Data 2

Description

Remarks

N1

 

N2

Sec

N1: Tens digit of EOM time

 

 

 

 

N2: Units digit of EOM time

 

 

 

 

(00, 05, 10, 15, 20, 25, 30, or 35)

F

 

F

EOM time request

Requests the EOM time

·If the specified data is other than described above, the controlled device sends ILLEGAL [F2].

12

TEAC Corporation

Page 12
Image 12