4-14. FADE IN/OUT TIME PRESET
Sets the fade in and out time from 1 to 10 seconds in 1 second steps.
When this command is transmitted with request data ([00FF] or [01FF]), the controlled device returns the FADE IN/OUT TIME RETURN command [AE].
The FADE mode is turned on and off using the FADE IN/OUT SELECT command [3E].
| Command | 2E |
|
| |
| Data | 4 bytes |
|
| |
| Return | FADE IN/OUT TIME RETURN [AE] |
| ||
|
|
|
|
|
|
Data 1 |
| Data 2 | Data 3 | Data 4 | Remarks |
0 |
| 0 | Tens digit of Fade In time | Units digit of Fade In time | Sets the Fade In time |
0 |
| 0 | F | F | Requests the Fade In |
|
|
|
|
| time |
0 |
| 1 | Tens digit of Fade Out time | Units digit of Fade Out time | Sets the fade Out time |
0 |
| 1 | F | F | Requests the Fade |
|
|
|
|
| Out time |
·If the specified data is other than described above, the controlled device sends ILLEGAL [F2].
·If the specified data is out of range, the controlled device sends ILLEGAL [F2].
4-15. AUTO CUE SELECT
Turns the Auto Cue function on and off.
When this command is transmitted with request data ([FF]), the controlled device returns the AUTO CUE SELECT RETURN command [B0].
The Auto Cue level is set using the AUTO CUE LEVEL PRESET command [20].
Command | 30 |
| ||
Data |
| 2 bytes |
| |
Return | AUTO CUE SELECT RETURN [B0] | |||
|
|
|
|
|
Data 1 |
| Data 2 | Description | Remarks |
0 |
| 0 | AUTO CUE MODE OFF | Turns the Auto Cue function off |
0 |
| 1 | AUTO CUE MODE ON | Turns the Auto Cue function on |
F |
| F | Auto Cue mode status request | Requests the Auto Cue mode status |
·If the specified data is other than described above, the controlled device sends ILLEGAL [F2].
4-16. EOM TRACK TIME SELECT
Sets the EOM (End of message) time.
When this command is transmitted with request data ([FF]), the controlled device returns the EOM TRACK TIME RETURN command [B2].
The EOM time should be set to 00, 05, 10, 15, 20, 25, 30, or 35.
Command | 32 |
| ||
Data |
| 2 bytes |
| |
Return | EOM TRACK TIME RETURN [B2] | |||
|
|
|
|
|
Data 1 |
| Data 2 | Description | Remarks |
N1 |
| N2 | Sec | N1: Tens digit of EOM time |
|
|
|
| N2: Units digit of EOM time |
|
|
|
| (00, 05, 10, 15, 20, 25, 30, or 35) |
F |
| F | EOM time request | Requests the EOM time |
·If the specified data is other than described above, the controlled device sends ILLEGAL [F2].