TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications
25 TEAC Corporation
5-23. PGM TOTAL TRACK No./TOTAL TIME RETURN
Transmitted in response to a PGM TOTAL TRACK No./TOTAL TIME SENSE command [5E], giving the
total number of the programmed tracks and the running time of the programmed tracks.
Command DE
Data 12 bytes
Request command PGM TOTAL TRACK No./TOTAL TIME SENSE [5E]
Description Remarks
Data 1 Tens digit of total tracks
Data 2 Units digit of total tracks
Data 3 Thousands digit of total tracks
Data 4 Hundreds digit of total tracks
Data 5 Tens digit of minutes
Data 6 Units digit of minutes
Data 7 Thousands digit of minutes
Data 8 Hundreds digit of minutes
Data 9 Tens digit of seconds
Data 10 Units digit of seconds
Data 11 Tens digit of frames
Data 12 Units digit of frames
5-24. ERROR SENSE REQUEST
Transmitted from the controlled device to the external controller to indicate an error condition. On
receipt of this message, the external controller should issue an ERROR SENSE request [78] in order to
determine the error type.
Command F0
Data None
Request command None
5-25. ILLEGAL STATUS
Transmitted from the controlled device to the external controller in order to indicate illegal status,
caused by an invalid command having been received. The external controller does not need to reply to
this message (though it may, of course, attempt to re-send a corrected version of the message, etc.)
Command F2
Data None
Request command None
5-26. POWER ON STATUS
Transmitted from the controlled device to the external controller in order to signal power-up.
Command F4
Data None
Request command None
5-27. CHANGE STATUS
Transmitted from the controlled device to the external controller. There are two types of change which
may be transmitted, each or which requires a reply by the external controller, as explained below.
Command F6
Data 2 bytes
Request command None
Data 1 Data 2 Description Remarks
0 0 Mechanism Status Change Mechanism status has been changed
0 3 Track Status Changes Track number or EOM status has been changed