Tascam CD-01U PGM Total Track No./TOTAL Time Return, Error Sense Request, Illegal Status

Models: CD-01U

1 26
Download 26 pages 28.73 Kb
Page 25
Image 25

TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications

5-23. PGM TOTAL TRACK No./TOTAL TIME RETURN

Transmitted in response to a PGM TOTAL TRACK No./TOTAL TIME SENSE command [5E], giving the total number of the programmed tracks and the running time of the programmed tracks.

Command

DE

Data

 

12 bytes

Request command

PGM TOTAL TRACK No./TOTAL TIME SENSE [5E]

 

 

 

 

 

Description

 

Remarks

Data 1

Tens digit of total tracks

 

Data 2

Units digit of total tracks

 

Data 3

Thousands digit of total tracks

 

Data 4

Hundreds digit of total tracks

 

Data 5

Tens digit of minutes

 

Data 6

Units digit of minutes

 

Data 7

Thousands digit of minutes

 

Data 8

Hundreds digit of minutes

 

Data 9

Tens digit of seconds

 

Data 10

Units digit of seconds

 

Data 11

Tens digit of frames

 

Data 12

Units digit of frames

 

5-24. ERROR SENSE REQUEST

Transmitted from the controlled device to the external controller to indicate an error condition. On receipt of this message, the external controller should issue an ERROR SENSE request [78] in order to determine the error type.

CommandF0

DataNone Request command None

5-25. ILLEGAL STATUS

Transmitted from the controlled device to the external controller in order to indicate illegal status, caused by an invalid command having been received. The external controller does not need to reply to this message (though it may, of course, attempt to re-send a corrected version of the message, etc.)

CommandF2

DataNone Request command None

5-26. POWER ON STATUS

Transmitted from the controlled device to the external controller in order to signal power-up.

CommandF4

DataNone Request command None

5-27. CHANGE STATUS

Transmitted from the controlled device to the external controller. There are two types of change which may be transmitted, each or which requires a reply by the external controller, as explained below.

Command

F6

 

Data

 

2 bytes

 

Request command None

 

 

 

 

 

 

Data 1

 

Data 2

Description

Remarks

0

 

0

Mechanism Status Change

Mechanism status has been changed

0

 

3

Track Status Changes

Track number or EOM status has been changed

25

TEAC Corporation

Page 25
Image 25
Tascam CD-01U PGM Total Track No./TOTAL Time Return, Error Sense Request, Illegal Status, Power on Status, Change Status