TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications

5-28. ERROR SENSE RETURN

Transmitted in response to an ERROR SENSE command [78], giving the specific error that has occurred.

Command

 

F8

 

Data

 

4 bytes

 

Request command

ERROR SENSE [78]

 

 

 

 

 

 

Data 1

N2

 

Error code( N1-N2N3)

 

Data 2

N3

 

1-01

TOC Read Error

Data 3

0

 

1-02

GFS Error

Data 4

N1

 

1-03

Focus servo Error

 

 

 

1-04 Sub Q Reading Error

 

 

 

1-05 Disk loading Error

 

 

 

1-06

Sled Error

 

 

 

1-10 SDRAM check Error

 

 

 

1-13

System Error

 

 

 

 

 

***Your unit must be version V1.02 for these commands to be supported.

(for update instructions please visit www.tascam.com)

26

TEAC Corporation

Page 26
Image 26
Tascam CD-01U specifications Error Sense Return