PROBLEM

PROBABLE CAUSE

REMEDY

PAGE

 

 

 

 

REF.

 

 

 

 

 

1.

No product being

a. Power switch is in the “OFF”

a. Place power switch in the

15

 

dispensed.

position.

“AUTO” position.

 

 

 

b. Improper mixing of product.

b. Carefully follow directions

-- -- --

 

 

 

for mixing product.

 

 

 

c. Inadequate mix in hopper.

c. Fill hopper with mix.

16

 

 

d. Product frozen--up in freezing

d. Adjust viscosity adjustment

10

 

 

cylinder.

accordingly.

 

 

 

e. Unit out on reset.

e. Place power switch in the

10

 

 

 

“OFF” position. Press the

 

 

 

 

reset button. Return

 

 

 

 

control switch to “AUTO”.

 

 

 

f. Beater assembly is not

f. The power switch must be

1

 

 

rotating at all or

in “AUTO”. If beater is

 

 

 

counterclockwise. Control

rotating counterclockwise,

 

 

 

switch is not in “AUTO”.

call service technician to

 

 

 

 

correct rotation.

 

 

 

g. Unit is unplugged.

g. Plug in power cord.

-- -- --

 

 

h. Tripped circuit breaker or

h. Reset circuit breaker or

-- -- --

 

 

blown fuse.

replace fuse.

 

 

 

 

 

2. Unit will not operate in the

a. Unit unplugged at wall

a. Plug in power cord.

-- -- --

 

“AUTO” or “WASH” mode.

receptacle.

 

 

 

 

b. Tripped circuit breaker or

b. Reset circuit breaker or

-- -- --

 

 

blown fuse.

replace fuse.

 

 

 

c. Unit out on reset.

c. Place the power switch in

10

 

 

 

the “OFF” position. Press

 

 

 

 

the reset button. Return

 

 

 

 

control switch to “AUTO”.

 

 

 

 

 

 

3.

No compressor operation

a. Beater motor is out on

a. Place control switch in

10

 

in the “AUTO” mode.

overload.

“OFF” position. Press the

 

 

 

 

reset button. Return

 

 

 

 

control switch to “AUTO”.

 

 

 

b. Condenser dirty A/C.

b. Clean condenser monthly.

18

 

 

 

 

 

4.

Product too thick.

a. Inadequate mix in hopper.

a. Fill hopper with mix.

16

 

 

b. Improper mixing of product.

b. Carefully follow directions

-- -- --

 

 

 

for mixing product.

 

 

 

c. The viscosity adjustment is

c. Adjust the viscosity control.

10

 

 

set incorrectly.

 

 

 

 

d. The torque arm is not

d. Install the torque arm.

13

 

 

installed.

 

 

 

 

 

 

 