34 Model C722Operating Procedures
120507
Note: If the agitator should stop turning during
normal operation, with sanitized hands, r emove
agitator from agitator drive shaft housing and brus h
clean with sanitizing solution. Install the agitator
back onto the agitator drive shaft housing.
Repeat these steps for the other sid e of the
machine.
Note: Be sure your hands are clean and
sanitized before proceeding wi th these
instructions.
PrimingNote: Use only FRESH MIX when priming the
freezer.
Step 1
Place an empty mix pail beneath the door spouts.
With the prime plug in the UP position, pour 2-1/2
gallons (9.5 liters) of FRESH mix into the mix hopper
and allow it to flow into the freezing cylinder.
Step 2
Open the draw valve to remove all sanitizing
solution. When only fresh mix is flowing, close the
draw valve.
Step 3
Once a steady stream of mix starts t o flow from the
prime plug opening in the bottom of the freezer door,
push the prime plug down.
Step 4
When mix stops bubbling down into the freezing
cylinder, remove the cotter pin from the out let fitting
of the mix pump. Insert the outlet end of the mix
feed tube into the mix inlet hole in the mix hopper.
Place the inlet end of the mix feed tube into the
outlet fitting of the mix pump. Secure with c otter pin.
Figure 75
Step 5
Select the AUTO symbol .
Note: The brush clean counter will start at this t ime.
Step 6
Fill the hopper with fresh mix and place the mix
hopper cover in position.
Repeat these steps for the other sid e of the
machine.
Manual Brush CleaningThis ProcedureMust Be Completed Every Day
ALWAYS FOLLOW LOCAL HEALTH CODES.
To disassemble the Model C722, the following items
will be needed:
STwo cleaning and sanitizing pails
SSanitizer/Cleaner
SNecessary brushes (provided with freezer)
SSingle service towels