2Model C722To the Installer
This unit must be installed on a level surface
to avoid the hazard of tipping. Extreme care should
be taken in moving this equipment for any reason.
Two or more people are required to safely move this
unit. Failure to comply may result in personal injury
or equipment damage.
Uncrate the unit and inspect it for damage. Report
any damage to your Taylor Distributor.
This piece of equipment is made in the USA and has
USA sizes of hardware. All metric conversions are
approximate and vary in size.
Water Connections(Water Cooled Units Only)
An adequate cold water supply must be provided
with a hand shut-off valve. On the underside of the
base pan or on the right side, two 3/8” I.P.S. water
connections for inlet and outlet are provided for easy
hook-up. 1/2” inside diameter water lines should be
connected to the machine. (Flexible lines are
recommended, if local codes permit.) Depending on
local water conditions, it may be advisable to install
a water strainer to prevent foreign substances f rom
clogging the automatic water valve. There will be
only one water “in” and one water “out” connection.
DO NOT install a hand shut-off valve on the water
“out” line! Water should always flow in this order:
First, through the automatic water valv e; second,
through the condenser; and third, through the outlet
fitting to an opentrapdrain.
A back flow prevention devi ce is
required on theincoming water connection side.
Please refer to the applicable National, State, and
local codes for determining the proper configuration.
Electrical ConnectionsIn the United States, this equipment is intended t o
be installed in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70-1987. The
purpose of the NEC is the practical safeguarding of
persons and property from hazards arising from the
use of electricity. This code contains provis ions
considered necessary for safety. In all other areasof
the world, equipment should be installed in
accordance with the existing local codes. Please
contact your local authorities.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
Each unit requires one power supply for each data
label on the unit. Check the data label(s) on the
freezer for branch circuit overcurrent prot ection or
fuse, circuit ampacity, and other electrical
specifications. Refer to the wiring diagram provided
inside of the electrical box for proper power
connections.
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
DO NOT operate this freezer with larger
fuses than specified on the unit data label. Failure to
follow this instruction may result in electrocut ion or
damage to the machine.
This unit is provided with an equipotential
grounding lug that is to be properly attached to the
rear of the frame by the authorized installer. T he
installation location is marked by the equipotential
bonding symbol (5021 of IEC 60417-1) on both the
removable panel and the equipment's frame.
Stationary appliances which are not
equipped with a power cord and a plug or another
device to disconnect the appliance from the power
source, must have an all-pole disconnecting device
with a contact gap of at least 3 mm installed in the
external installation.
Appliances that are permanently connected
to fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected or
not used for long periods, or during initial installation,
shall have protective devices such as a GFI, t o
protect against the leakage of current, installed by
the authorized personnel to the local codes.