2Model C043To the Installer
111216
This unit must be installed on a level surface
to avoid the hazard of tipping. Extreme care s hould be
taken in moving this equipment for anyreason. Two or
more persons are required to safely move t his unit.
Failure to comply may result in personal injur y or
equipment damage.
Uncrate the unit and inspect it for damage. Report any
damage to your Taylor Distributor.
This piece of equipment is made in the USA and has
USA sizes of hardware. All metric conversions are
approximate and vary in size.
Electrical ConnectionsIn the United States, this equipment isintended tobe
installed in accordance with the National Electrical
Code (NEC), ANSI/NFPA 70-1987. The purpose of
the NEC code is the practical safeguarding of persons
and property from hazards arising from the use of
electricity. This code contains provisions considered
necessary for safety. In all other areas of the world,
equipment should be installed in accordance with the
existing local codes. Please contact your local
authorities.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
Each unit requires one power supply for each data
label on the unit. Check the data label on the freezer
for branch circuit overcurrent protection or fuse, c ircuit
ampacity and other electrical specific ations. Refer to
thewiring diagr am provided inside the electrical box for
proper power connections.
CAUTION: THIS EQUIPMENT M UST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
DO NOT operate this freezer with larger f uses
than specified on the unit's data label. Failure to f ollow
this instruction may result in electrocution or dam age
to the machine.
This unit is provided with an equipotential
grounding lug that is to be properly attached to the rear
oft he frame by the authorized installer. The inst allation
location is marked by the equipotential bonding
symbol (5021 of IEC 60417-1) on both the removable
panel and the equipment's frame.
Stationary appliances which are not equipped
with a power cord and a plug or another device to
disconnect the appliance from the power source must
have an all-pole disconnecting device with a contact
gap of at least 3 mm installed in t he external
installation.
Appliances that are permanently connect ed to
fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected, not
used for long periods, or during initial installation, shall
have protective devices such as a GFI to protect
against the leakage of current, installed by the
authorized personnel to the local codes.
Supply cords used with this unit shall be
oil-resistant, sheathed flexible cable not lighter than
ordinary polychloroprene or other equivalent synthetic
elastomer-sheathed cord (Code designation 60245
IEC 57) installed with the proper cord anchorage to
relieve conductors from strain, including twist ing, at
the terminals and protect the insulation of t he
conductors from abrasion.
Beater rotation must be counter-clockwise
as viewed looking into the freezing cylinder.
Note: The following proceduresshould be
performed by a trained service techni cian.
To correct rotation on a three-phase unit,
interchange any two incoming power supply lines at
the freezer main terminal block only.
To correct rotation on a single-phase unit, change
the leads inside the beater motor. (Follow diagram
printed on motor.)
Electrical connections are made directly to the
terminal block provided behind the lower rear panel.