Advance Data Sheet: FReta iEB Series
Absolute Maximum Ratings: |
|
|
|
|
Stress in excess of Absolute Maximum Ratings may cause permanent damage to the device |
| |||
Characteristic | Min | Max | Unit | Notes & Conditions |
Continuous Input Voltage | 75 | Vdc |
|
| Transient Input Voltage | Vdc |
| ||
|
|
|
|
|
|
| Isolation Voltage | 2250 | Vdc | Basic insulation | |
|
|
|
|
|
|
| Storage Temperature | 125 | ˚C |
| |
|
|
|
|
|
|
|
|
|
|
| Measured at the location specified in the thermal |
|
|
|
|
| |
|
|
|
|
| measurement figure. Maximum temperature varies |
| Operating Temperature Range (Tc) | 123* | ˚C | with model number, output current, and module | |
|
|
|
|
| orientation – see curve in thermal performance |
|
|
|
|
| section of the data sheet. |
|
|
|
|
|
|
*Engineering estimation |
|
|
|
|
Input Characteristics:
Unless otherwise specified, specifications apply over all Rated Input Voltage, Resistive Load, and Temperature conditions.
Characteristic | Min | Typ | Max | Unit | Notes & Conditions |
Operating Input Voltage | 38 | 48 | 53 | Vdc |
|
Maximum Input Current | 6.5* | A | Vin = 0 to Vin,max | ||
|
|
|
|
|
|
36 | Vdc |
| |||
|
|
|
|
|
|
31* | 34.5 | Vdc |
| ||
|
|
|
|
|
|
Hysteresis | 0.5* | 1.5 | Vdc |
| |
|
|
|
|
|
|
Startup Delay Time from application of input | 3 | mS | Vo = 0 to 0.1*Vo,nom; on/off =on, | ||
voltage |
|
|
|
| Io=Io,max, Tc=25˚C |
|
|
|
|
|
|
Startup Delay Time from on/off | 3 | mS | Vo = 0 to 0.1*Vo,nom; Vin = Vi,nom, | ||
|
|
|
|
| Io=Io,max,Tc=25˚C |
|
|
|
|
|
|
Output Voltage Rise Time | 4 | mS | Io=Io,max,Tc=25˚C, Vo=0.1 to 0.9*Vo,nom | ||
|
|
|
|
|
|
Input | 61 | Vdc | Input rising | ||
|
|
|
|
|
|
Input | 59 | Vdc | Input falling | ||
|
|
|
|
|
|
Input | 2 | Vdc |
| ||
|
|
|
|
|
|
Inrush Transient | 0.2 | A2s |
| ||
|
|
|
|
|
|
Input Reflected Ripple | 50 | mApp | See input/output ripple and noise | ||
|
|
|
|
| measurements figure; BW = 20 MHz |
|
|
|
|
|
|
*Engineering estimation |
|
|
|
|
|
Caution: The power modules are not internally fused. An external input line normal blow fuse with a maximum value of 10A is required; see the Safety Considerations section of the data sheet.
(877) | |
10/29/2007 | 4/12 |
| |
|
|