TDK iEB Series Absolute Maximum Ratings, Input Characteristics, Unit, Notes & Conditions, 4/12

Models: iEB Series

1 12
Download 12 pages 38.51 Kb
Page 4
Image 4
Absolute Maximum Ratings:

Advance Data Sheet: FReta iEB Series –Single Output Eighth Brick Bus Converter

Absolute Maximum Ratings:

 

 

 

 

Stress in excess of Absolute Maximum Ratings may cause permanent damage to the device

 

Characteristic

Min

Max

Unit

Notes & Conditions

Continuous Input Voltage

-0.5

75

Vdc

 

 

Transient Input Voltage

---

---

Vdc

 

 

 

 

 

 

 

 

Isolation Voltage

---

2250

Vdc

Basic insulation

 

 

 

 

 

 

 

Storage Temperature

-55

125

˚C

 

 

 

 

 

 

 

 

 

 

 

 

Measured at the location specified in the thermal

 

 

 

 

 

 

 

 

 

 

measurement figure. Maximum temperature varies

 

Operating Temperature Range (Tc)

-40

123*

˚C

with model number, output current, and module

 

 

 

 

 

orientation – see curve in thermal performance

 

 

 

 

 

section of the data sheet.

 

 

 

 

 

 

*Engineering estimation

 

 

 

 

Input Characteristics:

Unless otherwise specified, specifications apply over all Rated Input Voltage, Resistive Load, and Temperature conditions.

Characteristic

Min

Typ

Max

Unit

Notes & Conditions

Operating Input Voltage

38

48

53

Vdc

 

Maximum Input Current

---

---

6.5*

A

Vin = 0 to Vin,max

 

 

 

 

 

 

Turn-on Voltage

---

36

---

Vdc

 

 

 

 

 

 

 

Turn-off Voltage

31*

34.5

---

Vdc

 

 

 

 

 

 

 

Hysteresis

0.5*

1.5

---

Vdc

 

 

 

 

 

 

 

Startup Delay Time from application of input

---

3

---

mS

Vo = 0 to 0.1*Vo,nom; on/off =on,

voltage

 

 

 

 

Io=Io,max, Tc=25˚C

 

 

 

 

 

 

Startup Delay Time from on/off

---

3

---

mS

Vo = 0 to 0.1*Vo,nom; Vin = Vi,nom,

 

 

 

 

 

Io=Io,max,Tc=25˚C

 

 

 

 

 

 

Output Voltage Rise Time

---

4

---

mS

Io=Io,max,Tc=25˚C, Vo=0.1 to 0.9*Vo,nom

 

 

 

 

 

 

Input Over-voltage Turn-off

---

61

---

Vdc

Input rising

 

 

 

 

 

 

Input Over-voltage Turn-on

---

59

---

Vdc

Input falling

 

 

 

 

 

 

Input Over-voltage Hysteresis

---

2

---

Vdc

 

 

 

 

 

 

 

Inrush Transient

---

---

0.2

A2s

 

 

 

 

 

 

 

Input Reflected Ripple

---

50

---

mApp

See input/output ripple and noise

 

 

 

 

 

measurements figure; BW = 20 MHz

 

 

 

 

 

 

*Engineering estimation

 

 

 

 

 

Caution: The power modules are not internally fused. An external input line normal blow fuse with a maximum value of 10A is required; see the Safety Considerations section of the data sheet.