Cypress CY7C139, CY7C138 manual Maximum Ratings, Operating Range, Range Ambient, Temperature

Models: CY7C138 CY7C139

1 17
Download 17 pages 32.5 Kb
Page 3
Image 3

CY7C138, CY7C139

Maximum Ratings

 

 

 

 

 

 

 

Output Current into Outputs (LOW)

 

20 mA

Exceeding maximum ratings may impair the useful life of the

 

Static Discharge Voltage

 

 

 

 

>2001V

 

(per MIL-STD-883, Method 3015)

 

 

 

 

 

 

device. These user guidelines are not tested.[5]

 

 

 

 

 

 

 

 

 

 

 

 

Latch-Up Current

 

 

 

 

 

>200 mA

Storage Temperature

–65°C to +150°C

 

 

 

 

 

 

 

Operating Range

 

 

 

 

 

 

 

 

Ambient Temperature with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Applied

–55°C to +125°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

 

Ambient

 

 

VCC

 

 

Supply Voltage to Ground Potential

 

–0.5V to +7.0V

 

 

 

 

 

 

 

 

 

 

 

Temperature

 

 

 

 

DC Voltage Applied to Outputs

 

 

 

 

 

 

 

Commercial

 

0°C to +70°C

 

 

5V ± 10%

 

 

in High Z State

 

–0.5V to +7.0V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Industrial

 

–40°C to +85°C

 

 

5V ± 10%

 

 

DC Input Voltage[6]

 

–0.5V to +7.0V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Characteristics Over the Operating Range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7C138-15

 

7C138-25

 

 

 

Parameter

Description

 

 

 

 

 

Test Conditions

 

7C139-15

 

7C139-25

 

Unit

 

 

 

 

 

 

 

 

 

 

 

 

Min

Max

 

Min

Max

 

 

 

VOH

Output HIGH Voltage

 

VCC = Min., IOH = –4.0 mA

 

 

2.4

 

 

2.4

 

 

V

VOL

Output LOW Voltage

 

VCC = Min., IOL = 4.0 mA

 

 

 

0.4

 

 

 

0.4

 

V

VIH

 

 

 

 

 

 

 

 

 

 

 

2.2

 

 

2.2

 

 

V

VIL

Input LOW Voltage

 

 

 

 

 

 

 

 

 

 

 

0.8

 

 

 

0.8

 

V

IIX

Input Leakage Current

 

GND < VI < VCC

 

 

 

 

–10

+10

 

–10

+10

 

μA

IOZ

Output Leakage Current

 

Output Disabled, GND < VO < VCC

 

–10

+10

 

–10

+10

 

μA

ICC

Operating Current

 

VCC = Max.,

 

 

Commercial

 

 

220

 

 

 

180

 

mA

 

 

 

IOUT = 0 mA,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Industrial

 

 

 

 

 

 

190

 

 

 

 

 

 

Outputs Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

ISB1

Standby Current

 

CE

L and

CE

R > VIH,

Commercial

 

 

60

 

 

 

40

 

mA

 

(Both Ports TTL Levels)

 

f = fMAX[7]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Industrial

 

 

 

 

 

 

50

 

 

 

ISB2

Standby Current

 

CE

L and

CE

R > VIH,

Commercial

 

 

130

 

 

 

110

 

mA

 

(One Port TTL Level)

 

f = fMAX[7]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Industrial

 

 

 

 

 

 

120

 

 

 

ISB3

Standby Current

 

Both Ports

 

 

 

 

Commercial

 

 

15

 

 

 

15

 

mA

 

(Both Ports CMOS Levels)

 

CE and CER > VCC – 0.2V,

 

 

 

 

 

 

 

 

 

 

 

 

 

Industrial

 

 

 

 

 

 

30

 

 

 

 

 

 

VIN > VCC

– 0.2V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or VIN < 0.2V, f = 0[7]

 

 

 

 

 

 

 

 

 

 

 

ISB4

Standby Current

 

One Port

 

 

 

 

Commercial

 

 

125

 

 

 

100

 

mA

 

(One Port CMOS Level)

 

CEL or CER > VCC

– 0.2V,

 

 

 

 

 

 

 

 

 

 

 

 

 

Industrial

 

 

 

 

 

 

115

 

 

 

 

 

 

VIN > VCC

– 0.2V or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIN < 0.2V, Active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port Outputs, f = fMAX[7]

 

 

 

 

 

 

 

 

 

 

 

Notes

5.The Voltage on any input or I/O pin cannot exceed the power pin during power-up.

6.Pulse width < 20 ns.

7.fMAX = 1/tRC = All inputs cycling at f = 1/tRC (except output enable). f = 0 means no address or control lines change. This applies only to inputs at CMOS level standby ISB3.

Document #: 38-06037 Rev. *D