100 Mb Fiber Transceiver Characteristics

Fiber Length

2km*

15km**

40km**

80km**

 

 

 

 

 

TX Power Min/Max

-19dBm/-14dBm

-15dBm/-7dBm

-5dBm/0dBm

-5dBm/0dBm

 

 

 

 

 

RX Sensitivity Max

-32dBm

-29dBm

-34dBm

-34dBm

 

 

 

 

 

Wavelength Min/Max

1310nm

1310dm

1310dm

1550nm

 

 

 

 

 

*Multimode Fiber Optic Cable

**Singlemode Fiber Optic Cable

Gigabit Fiber Transceiver (SFP) Characteristics

Fiber Length

550m* with

10km**

40km**

70km**

 

50/125 µm

 

 

 

TX Power Min/Max

-9.5dBm/-4dBm

-9.5dBm/-3.5dBm

-2dBm/3dBm

0dBm/5dBm

 

 

 

 

 

 

RX Sensitivity Max

-17dBm

-20dBm

-22dBm

-24dBm

 

 

 

 

 

 

Wavelength

850nm

1310nm

1310nm

1550nm

 

 

 

 

 

Assumed Fiber Loss

 

-0.5 dB/km

-0.35 dB/km

-0.25 dB/km

 

 

 

 

 

Laser Type

VCSEL

FP

DFB

DFB

 

 

 

 

 

*SX Fiber Optic Cable ** LX Fiber Optic Cable

Regulatory Approvals:

Safety: UL Listed per ANSI/ISA-12.12.01-2000 (US and Canada) and listed for use in Class I, Div 2, Groups A, B, C, and D, T4

EMI: EN 61000-6-4, EN 55011 – Class A

FCC Title 47, Part 15, Subpart B - Class A

ICES-003 – Class A

EMS: EN 61000-6-2

IEC 61000-4-2 (ESD)

IEC 61000-4-3 (RS)

IEC 61000-4-4 (EFT)

IEC 61000-4-5 (Surge)

IEC 61000-4-6 (Conducted Disturbances)

GOST-R Certified.

Warranty: Effective January 1, 2008, all N-TRON products carry a 3 year limited warranty from the date of purchase.