Set Flow Control

Command Name

port set flowcontrol

Description

Enable or Disable flow control (typically refers to 100Base). When

 

enabled a pause frame will be sent to help control the flow.

Syntax

port set flowcontrol <port-no><enable disable>

Parameters

port-no

 

port number (1 ~ 12)

 

enable disable

 

Flow Control enable or disable

Examples

N-TRON/Admin#[1]> port set flowcontrol 6 enable

NOTES

Check whether port-nois in the valid range. (1 ~ 12)

Set Name

 

Command Name

port set name

Description

Changes the name of the port. This change will only be visible in the CLI.

Syntax

port set name <port-no><name>

Parameters

port-no

 

port number (1 ~ 14)

 

name

 

A string that describes the port

Examples

N-TRON/Admin#[1]> port set name 6 waterplant

NOTES

This will be reset if you change a slot configuration.

Set PVID

 

Command Name

port set pvid

Description

Set a port’s VLAN-ID.

Syntax

port set pvid <port-no><pvid-number>

Parameters

port-no

 

port number (1 ~ 14)

 

pvid-number

 

The VLAN-ID number of the VLAN that this port will be a member of

Examples

N-TRON/Admin#[1]> port set pvid 6 2

NOTES

A port can be a member to several VLANs, but can only have one PVID

Set Backpressure

 

Command Name

port set backpressure

Description

Enables or disables backpressure on a given port. This is normally used on

 

10Base setups and is a controlled by the hardware.

Syntax

port set backpressure <port-no><enable disable>

Parameters

port-no

 

port number (1 ~ 12)

 

enable disable

 

Backpressure enable or disable

Examples

N-TRON/Admin#[1]> port set backpressure 6 enable

NOTES

Check whether port-nois in the valid range. (1 ~ 12)

Set Intruderstate

 

Command Name

port set intruderstate

Description

Enables or Disables the intruder log.

Syntax

port set intruderstate <enable disable>

Parameters

enable disable

 

Enable or disable the intruder log

Examples

N-TRON/Admin#[1]> port set intruderstate enable

NOTES

This must be enabled for the intruder log to log anything.