(10/30)

JBW75W Type

SPECIFICATIONS AND STANDARDS

Part No.

 

 

JBW05-15R

JBW12-6R3

JBW15-5R0

JBW24-3R2

Rated output voltage and current

 

5V • 15A

12V • 6.3A

15V • 5.0A

24V • 3.2A

Maximum output power

W

75

75.6

75

76.8

Input conditions

 

 

 

 

 

Input voltage Eac/Edc

V

85 to 265[Rating: 100-240]/120 to 370

 

 

Input frequency

Hz

47 to 66

 

 

 

Input current

A

1.6/0.8max.[100-240V]

 

 

 

Fuse rating

A

3.15

 

 

 

Surge current

A

30/60max.[100-240V]

 

 

 

Leakage current

mA

0.75/0.75max.[AC.100V(DENAN)/240V(UL, IEC)]

 

 

Power factor

 

0.99/0.95typ.[100-240V]

 

 

 

Efficiency

 

%

75/77typ.

78/80typ.

79/81typ.

82/84typ.

 

[100-240V]

[100-240V]

[100-240V]

[100-240V]

 

 

 

 

Output characteristics

 

 

 

 

 

Output voltage Edc

V

5

12

15

24

Voltage variable range Edc

V

4.5 to 5.5

10.8 to 13.2

13.5 to 16.5

21.6 to 26.4

Maximum output current

A

15

6.3

5.0

3.2(Peak4.2)

Overvoltage threshold Edc

V

5.75 to 6.9

13.8 to 16.8

17.2 to 21

27.6 to 33.6

Overcurrent threshold

A

15.8min.

6.6min.

5.2min.

4.4min.

 

 

Source effect

%

0.4max.[Within the input voltage range]

 

 

Voltage

 

Load effect

%

0.8max.[0 to 100% load]

 

 

 

 

Temperature effect

%

1max.[Ambient temperature: –10 to +60°C]

 

 

stability

 

 

 

 

Drift(Time effect)

%

0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]

 

 

 

 

 

 

Recovery

%

±4max.[50 to 100% sudden load change]

 

 

Ripple Ep-p

mV

80

120

120

120

Ripple noise Ep-p

mV

120

150

150

150

Start up time

ms

500max.(400typ.)/250max.(200typ.)[AC.100/240V]

 

 

Hold up time

ms

20typ.[100-240V]

 

 

 

Auxiliary functions

 

 

 

 

 

Indicator display

 

No

 

 

 

Overvoltage protection

 

Voltage shut-down type(Latch).

 

 

Overcurrent protection

 

Rectangular type, automatic recovery.

 

 

Remote ON-OFF

 

No

 

 

 

Remote sensing

 

No

 

 

 

Standards

 

 

 

 

 

 

Safety standards

 

UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.

 

Noise terminal voltage

 

FCC-B, VCCI-B, EN55011-B, EN55022-B meet.

 

 

Input harmonics current requirement

EN61000-3-2

 

 

 

CE marking

 

Planned compliance.

 

 

 

Constructions

 

 

 

 

 

External dimensions

mm

3255222[HWL]

 

 

 

Weight

 

g

290max.

 

 

 

Mounting method

 

Can be attached to 1 side.

 

 

 

Case material

 

CEM3

 

 

 

• All specifications are subject to change without notice.

004-02 / 20070523 / ea122_jbw

Page 10
Image 10
TDK J Series JBW specifications JBW75W Type