(12/30)

004-02 / 20070523 / ea122_jbw.fm

• All specifications are subject to change without notice.
JBW100W Type
SPECIFICATIONS AND STANDARDS
Part No. JBW05-20R JBW12-8R5 JBW15-6R7 JBW24-4R3
Rated output voltage and current 5V • 20A 12V • 8.5A 15V • 6.7A 24V • 4.3A
Maximum output power W 100 102 100.5 103.2
Input conditions
Input voltage Eac/Edc V 85 to 265[Rating: 100-240]/120 to 370
Input frequency Hz 47 to 66
Input current A 1.8/1.0max.[100-240V]
Fuse rating A 5
Surge current A 30/60max.[100-240V]
Leakage current mA 0.75/0.75max.[AC.100V(DENAN)/240V(UL, IEC)]
Power factor 0.99/0.95typ.[100-240V]
Efficiency % 78/8 0typ.
[100-240V]
80/82typ.
[100-240V]
80/82typ.
[100-240V]
82/85typ.
[100-240V]
Output characteristics
Output voltage Edc V 5 12 15 24
Voltage variable range Edc V ±10% ±10% ±10% ±10%
Maximum output current A 20 8.5 6.7 4.3(Peak5)
Overvoltage threshold Edc V 5.75 to 6.9 13.8 to 16.8 17.2 to 21 27.6 to 33.6
Overcurrent threshold A 21.0min. 10.6min. 8.38min. 5.38min.
Voltage
stability
Source effect % 0.4max.[Within the input voltage range]
Load effect % 0.8max.[0 to 100% load]
Temperature effect % 1max.[Ambient temperature: –10 to +60°C]
Drift(Time effect) % 0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Recovery % ±4max.[50 to 100% sudden load change]
Ripple Ep-p mV 80 120 120 120
Ripple noise Ep-p mV 120 150 150 150
Start up time ms 500max.(400typ.)/500max.(300typ.)[AC.100/240V]
Hold up time ms 20typ.[100-240V]
Auxiliary functions
Indicator display No
Overvoltage protection Voltage shut-down type(Latch).
Overcurrent protection Rectangular type, automatic recovery.
Remote ON-OFF No
Remote sensing No
Standards
Safety standards UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.
Noise terminal voltage FCC-B, VCCI-B, EN55011-B, EN55022-B meet.
Input harmonics current requirement EN61000-3-2
CE marking Planned compliance.
Constructions
External dimensions mm 35×62×222[H×W×L]
Weight g 400max.
Mounting method Can be attached to 1 side.
Case material FR4