(6/30)
JBW30W Type
SPECIFICATIONS AND STANDARDS
Part No. |
|
|
|
| |||||
Rated output voltage and current∗ |
| 5V • 6A | 12V • 2.5A |
| 15V • 2A | 24V • 1.3A | |||
Maximum output power |
| W | 30 | 30 |
| 30 | 31.2 | ||
Input conditions |
|
|
|
|
|
| |||
Input voltage Eac/Edc |
| V | 85 to 265[Rating: 100 to 240]/110 to 370 |
|
| ||||
Input frequency |
| Hz | 47 to 440[Rating: 50 to 60](Single phase) |
|
| ||||
Input current |
| A | 0.65typ./0.86max.[AC.100V]0.35typ./0.48max.[AC.240V] |
|
| ||||
Fuse rating |
| A | 2[AC.250V, |
|
|
|
| ||
Surge current |
| A | 15typ./30max.[AC.100V]30typ./60max.[AC.240V] 1st surge current, cold start, reset after 1s minimum. | ||||||
Leakage current |
| mA | 0.35typ./0.75max.[AC.100V, 60Hz]0.5typ./0.75max.[AC.240V, 60Hz] |
| |||||
Power factor |
| 0.6typ./0.45typ.[AC.100/240V] |
|
| |||||
Efficiency |
|
| % | 75typ.[AC.100V] | 78typ.[AC.100V] |
| 79typ.[AC.100V] | 80typ.[AC.100V] | |
|
| % | 77typ.[AC.240V] | 79typ.[AC.240V] |
| 80typ.[AC.240V] | 81typ.[AC.240V] | ||
|
|
|
|
| |||||
Output characteristics |
|
|
|
|
|
| |||
Output voltage Edc |
| V | 5 | 12 |
| 15 | 24 | ||
Voltage variable range Edc |
| V | Fixed | Fixed |
| Fixed | Fixed | ||
Maximum output current |
| A | 6 | 2.5 |
| 2 | 1.3 | ||
Minimum output current |
| A | 0 | 0 |
| 0 | 0 | ||
Overvoltage threshold Edc |
| V | 5.6min. | 13.3min. |
| 16.6min. | 26.5min. | ||
Overcurrent threshold |
| A | 6.3min. | 2.7min. |
| 2.1min. | 1.4min. | ||
|
| Source effect |
| % | 0.4max.[Within the input voltage range] |
|
| ||
Voltage |
| Load effect |
| % | 0.8max.[0 to 100% load] |
|
|
|
|
| Temperature effect |
| % | 2max.[Ambient temperature: |
|
| |||
stability |
|
|
|
| |||||
| Drift(Time effect) |
| % | 0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h] |
| ||||
|
|
|
| ||||||
|
| Recovery |
| % | ±4max.[50 to 100% sudden load change] |
|
| ||
Ripple |
| mV | 80max. | 120max. |
| 120max. | 120max. | ||
Ripple noise |
| mV | 120max. | 150max. |
| 150max. | 150max. | ||
Start up time |
| ms | 650max.(350typ.)/320max.(130typ.)[AC.100/240V] |
|
| ||||
Hold up time |
| ms | 20typ./160typ.[AC.100/240V] |
|
| ||||
Auxiliary functions |
|
|
|
|
|
| |||
Indicator display |
| No |
|
|
|
| |||
Overvoltage protection |
| Voltage |
|
|
|
| |||
Overcurrent protection |
| Rectangular type(Winker operation), automatic recovery. |
|
| |||||
Remote |
| No |
|
|
|
| |||
Remote sensing |
| No |
|
|
|
| |||
Parallel operation |
| Impossible |
|
|
|
| |||
Series operation |
| Impossible |
|
|
|
| |||
Output voltage external variable function | No |
|
|
|
| ||||
Standards |
|
|
|
|
|
|
|
| |
Safety standards |
|
| |||||||
Noise terminal voltage |
|
|
| ||||||
Input harmonics current requirement | No |
|
|
|
| ||||
Constructions |
|
|
|
|
|
| |||
External dimensions |
| mm | 26⋅ 55⋅ 122[H⋅ W⋅ L] |
|
|
|
| ||
Weight |
|
| g | 150max. |
|
|
|
| |
Mounting method |
| Can be attached to 1 side. |
|
|
|
| |||
Case material |
| No(PWB Material: CEM3) |
|
|
|
|
∗Current rating(maximum output current) is determined for
• Optional input, output cable kits are available at a separate price.
• All specifications are subject to change without notice.