(4/30)

JBW15W Type

SPECIFICATIONS AND STANDARDS

Part No.

 

 

 

JBW05-3R0

JBW12-1R3

JBW15-1R0

JAW24-0R7

Rated output voltage and current

 

5V • 3A

12V • 1.3A

15V • 1.0A

24V • 0.7A

Maximum output power

 

W

15

15.6

15

16.8

Input conditions

 

 

 

 

 

Input voltage Eac/Edc

 

V

85 to 265[Rating: 100 to 240]/110 to 370

 

 

Input frequency

 

Hz

47 to 440[Rating: 50 to 60](Single phase)

 

 

Input current

 

A

0.36typ./0.43max.[AC.100V]0.2typ./0.24max.[AC.240V]

 

 

Fuse rating

 

A

2[AC.250V, built-in]

 

 

 

Surge current

 

A

15typ./19.5max.[AC.100V]30typ./41max.[AC.240V] 1st surge current, cold start, reset after 1s minimum.

Leakage current

 

mA

0.2typ./0.75max.[AC.100V, 60Hz]0.3typ./0.75max.[AC.240V, 60Hz]

 

Power factor

 

0.6typ./0.45typ.[AC.100/240V]

 

 

Efficiency

 

 

%

72typ.[AC.100V]

76typ.[AC.100V]

76typ.[AC.100V]

78typ.[AC.100V]

 

 

%

72typ.[AC.240V]

74typ.[AC.240V]

74typ.[AC.240V]

76typ.[AC.240V]

 

 

 

 

Output characteristics

 

 

 

 

 

Output voltage Edc

 

V

5

12

15

24

Voltage variable range Edc

 

V

Fixed

Fixed

Fixed

Fixed

Maximum output current

 

A

3

1.3

1

0.7

Minimum output current

 

A

0

0

0

0

Overvoltage threshold Edc

 

V

5.75min.

13.8min.

17.25min.

27.6min.

Overcurrent threshold

 

A

3.15min.

1.37min.

1.05min.

0.74min.

 

 

Source effect

 

%

0.4max.[Within the input voltage range]

 

 

Voltage

 

Load effect

 

%

0.8max.[0 to 100% load]

 

 

 

 

Temperature effect

 

%

1max.[Ambient temperature: –10 to +50°C]

 

 

stability

 

 

 

 

 

Drift(Time effect)

 

%

0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]

 

 

 

 

 

 

 

Recovery

 

%

±4max.[50 to 100% sudden load change]

 

 

Ripple Ep-p

 

mV

80max.

120max.

120max.

120max.

Ripple noise Ep-p

 

mV

120max.

150max.

150max.

150max.

Start up time

 

ms

200max.(25typ.)/100max.(25typ.)[AC.100/240V]

200max.(40typ.)/100max.(40typ.)[AC.100/240V]

Hold up time

 

ms

13typ./150typ. [AC.100/240V]

 

 

Auxiliary functions

 

 

 

 

 

Indicator display

 

No

 

 

 

Overvoltage protection

 

Zenor diode clamp method, output may latch up depending on the condition.

 

Overcurrent protection

 

Rectangular type, automatic recovery.

 

 

Remote ON-OFF

 

No

 

 

 

Remote sensing

 

No

 

 

 

Parallel operation

 

Impossible

 

 

 

Series operation

 

Impossible

 

 

 

Output voltage external variable function

No

 

 

 

Standards

 

 

 

 

 

 

 

Safety standards

 

UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.

 

Noise terminal voltage

 

FCC-B, VCCI-B, EN55011-B, EN55022-B meet.

 

 

Input harmonics current requirement

No

 

 

 

Constructions

 

 

 

 

 

External dimensions

 

mm

22.65095[HWL]

 

 

 

Weight

 

 

g

80max.

 

 

 

Mounting method

 

Can be attached to 1 side.

 

 

 

Case material

 

No(PWB Material: CEM3)

 

 

 

Current rating(maximum output current) is determined for –10 to +50°C. Derating is required when used outside this temperature range.

• Optional input, output cable kits are available at a separate price.

• All specifications are subject to change without notice.

004-02 / 20070523 / ea122_jbw