(14/30)

JBW150W Type

SPECIFICATIONS AND STANDARDS

Part No.

 

 

 

JBW05-30R

 

JBW12-12R

JBW15-10R

JBW24-6R3

JBW48-3R2

Rated output voltage and current

 

5V • 30A

 

12V • 12A

15V • 10A

24V • 6.3A

48V • 3.2A

Maximum output power

 

W

150

 

150

150

151.2

153.6

Input conditions

 

 

 

 

 

 

 

Input voltage Eac/Edc

 

V

85 to 265[Rating: 100-240]/120 to 370

 

 

 

Input frequency

 

Hz

47 to 66

 

 

 

 

Input current

 

A

2.7/1.5max.[100-240V]

 

 

 

Surge current

 

A

30/60max.[100-240V]

 

 

 

 

Leakage current

 

mA

0.75/0.75max.[AC.100V(DENAN)/240V(UL, IEC)]

 

 

Power factor

 

0.99/0.95typ.[100-240V]

 

 

 

Efficiency

 

 

%

78/80typ.

 

81/83typ.

81/83typ.

82/84typ.

82/84typ.

 

 

[100-240V]

 

[100-240V]

[100-240V]

[100-240V]

[100-240V]

 

 

 

 

 

 

Output characteristics

 

 

 

 

 

 

 

Output voltage Edc

 

V

5

 

12

15

24

48

Voltage variable range Edc

 

V

4.5 to 5.5

 

10.8 to 13.2

13.5 to 16.5

21.6 to 26.4

43.2 to 52.8

Maximum output current

 

A

30

 

12.5

10

6.3(Peak7.5)

3.2

Overvoltage threshold Edc

 

V

5.75 to 6.9

 

13.8 to 16.8

17.2 to 21

27.6 to 33.6

55.2 to 67.2

Overcurrent threshold

 

A

31.5min.

 

15.7min.

12.5min.

7.87min.

3.36min.

 

 

Source effect

 

%

0.4max.[Within the input voltage range]

 

 

 

Voltage

 

Load effect

 

%

0.8max.[0 to 100% load]

 

 

 

 

Temperature effect

 

%

1max.[Ambient temperature: –10 to +60°C]

 

 

 

stability

 

 

 

 

 

 

Drift(Time effect)

 

%

0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]

 

 

 

 

 

 

 

Recovery

 

%

±4max.[50 to 100% sudden load change]

 

 

 

Ripple Ep-p

 

mV

80max.

 

120max.

120max.

120max.

150max.

Ripple noise Ep-p

 

mV

120max.

 

150max.

150max.

150max.

350max.

Start up time

 

ms

500max.(400typ.)/500max.(300typ.)[AC.100/240V]

 

 

Hold up time

 

ms

25/35typ.[AC.100/240V]

 

 

 

Auxiliary functions

 

 

 

 

 

 

 

Indicator display

 

No

 

 

 

 

Overvoltage protection

 

Voltage shut-down type(Latch).

 

 

 

Overcurrent protection

 

Rectangular type, automatic recovery.

 

 

 

Remote ON-OFF

 

No

 

 

 

 

Remote sensing

 

No

 

 

 

 

Standards

 

 

 

 

 

 

 

 

 

Safety standards

 

UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.

 

Noise terminal voltage

 

FCC-B, VCCI-B, EN55011-B, EN55022-B meet.

 

 

Input harmonics current requirement

EN61000-3-2

 

 

 

 

CE marking

 

Meet.

 

 

 

 

Constructions

 

 

 

 

 

 

 

External dimensions

 

mm

4075222[HWL]

 

 

 

 

Weight

 

 

g

550max.

 

 

 

 

Mounting method

 

Can be attached to 1 side.

 

 

 

Case metal

 

FR4

 

 

 

 

Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.

• All specifications are subject to change without notice.

004-02 / 20070523 / ea122_jbw

Page 14
Image 14
TDK J Series JBW specifications JBW150W Type