ENGLISH

Description

1

Lid

11Cord holder

2

Viewing window

12Lid opening buttons

3aAnti-odour carbon filter

13Carrying handles when cold

3bFilter handling tabs

14Container fill tube

4

Basket

15Container lid cap (for emptying)

5

Basket release button

16“OIL BOX” oil/fat container

6

Handle for raising and lowering basket

17Drain button

7

Non-stick removable bowl

18Plug with cord

8

Bowl fill level marks (1L/2L)

19Control panel

9aFilter grid

20Temperature light

9bAutomatic drain valve

21Thermostat

10Housing

WORLDWIDE EXCLUSIVITY

Filtration, drainage and automatic storage of oil/fat

Oléoclean is fitted with an exclusive and patented system for filtration and automatic drainage, suitable for most types of oils and fats used for cooking.

Thanks to the OIL BOX container, you can store your oil or fat and keep it until you next want to use it.

-The drainage of oil is completely automatic and does not need any special handling, which makes it totally safe.

-Thanks to the automatic filtration system, your oil/fat stays clean and lasts longer for healthier frying.

-Separate OIL BOX containers can be used to store oil/fat used for frying different types of food (chips, fish, doughnuts, etc.) to avoid any transfer of flavours.

Dismantling the fryer

Open the lid by pressing on one of the two buttons and pull it away from the fryer

- Fig. 1

Remove the oil/fat container - Fig. 2 Lift the basket handle until you hear a “click” as it locks - Fig. 3 Remove the basket.

After pulling the cord towards the front, remove the control panel - Fig. 4 Take out the bowl from the housing.

Unscrew (1) the drain valve located on the bottom of the bowl.

Remove the drain valve (2) and filter grid

(3)- Fig. 5

Preparation for use

Cleaning the fryer

Remove the protective film from the underside of the viewing window (depending on model).

Clean all parts (except the control panel) with a sponge and washing-up liquid or put them through the dishwasher - Fig. 6 Dry them off.

For good visibility through the window, see chapiter Cleaning. Never immerse the control panel and cord in water. Ensure that the anti-odour filter is dry before frying.Reassembling the fryer

Important : while replacing the automatic drain valve ensure that the seal is placed correctly under the 3 lugs designed for this purpose.

Place the filter grid in the bowl (domed side facing you) - Fig. 7

Turn the bowl over holding the filter grid. Place (1) the automatic drain valve flat on position O.

Turn (2) to position I - Fig. 8

Replace the bowl then the control panel.