Technical Information | Installation |
If the equipment does not work, advise the Technical Service Department of the problem you have observed, indicating,
1Serial number
2Appliance model. (Model)
That you will find engraved on the characteristics plaque. This plaque is found on the lower part of the oven and can be seen when the door is open.
To help in identifying the oven, we recommend you write the following data:
Mod:
This information is purely for a qualified technician, as the person responsible for assembly and electrical connection. If you install the oven yourself, the manufacturer will not be held responsible for any possible damage.
Before Making the Installation.
Comments
• To unpack the oven, pull the tab located on |
the lower part of the box. To move it, hold it |
by the lateral handles and never by the |
oven door handle. |
• An opening is made in the kitchen unit with |
the dimensions appearing on the figure, |
ensuring a minimum depth of 580 mm. |
(See figures 1 and 2 describing oven fitting |
on the back cover). |
• To fit multifunction ovens, the back part of |
Electrical Connection.
Legal Requirements
The installer must check that:
•The voltage and cycles of the mains supply correspond to that indicated in the characteristics plaque.
•The electrical installation can stand the maximum power indicated in the characteristics plaque.
•To connect the oven to the electrical circuit, the installer must use a T150 type supply cable. The connection diagram is shown in the following figure:
•The electrical connection has adequate earthing in accordance with regulations in force.
•The connection must be carried out with an omnipolar switch, of an adequate size for the current drawn and with a minimum aperture between contacts of 3mm for disconnection in the case of emergency, cleaning or bulb exchange. Under no circumstances must the earth wire pass through this switch.
After making the electrical connection, verify the correct working of all the electrical parts of the oven.
ENGLISH
The item that you have bought meets the European directives on electrical material safety (73/23/CEE) and electromagnetic com- patibility (89/336/CEE).
the kitchen unit corresponding to the | ||
shaded area of figure 3, must not have any | ||
projections | (reinforcements, | pipes, |
sockets, etc). (See the back cover). |
| |
• The adhesive used for the plastic covering | ||
of the mit must be able to withstand | ||
temperatures of up to 85ºC. |
| |
• Our ovens may only be combined with TEKA | ||
cookers, otherwise the equipment may be | ||
damaged and safety compromised. |
| |
• For installing the work top cooker, refer to | ||
its instruction manual. |
|
230 V 1
N
L
3 x 1,5mm2 T 150
400 V 2N |
| |
N | L2 | L1 |
230 V 1 | |
N | L |
3 x 4mm2 T 150
400 V 3N |
| |
N | L2 | |
L3 | L1 |
4 x 2,5mm2 T 150 | 5 x 1,5mm2 T 150 |
36 | 37 |