3-5

System Overview

System Overview
The Standard Model 2200 system consists of a Switcher Frame, a Switcher
Frame Power Supply, a Control Panel and interconnecting cables.
Power Distribution
The Model 2200 Switcher Frame has a separate power supply (2 supplies if
the optional Redundant Power Supply is installed). This power supply is
connected to the switcher frame by 2 cables. Turn off the power supply(s)
before connecting or disconnecting the power cable. Installation and setup
of the power supplies is described in detail in Section 2 – Installation.
Replacement and maintenance of the power supplies is described in
Section 4 – Maintenance.

Input Voltage:

Switcher Frame: 208 to 240 volts 50 to 60 Hz.
Control Panel: 120 volts nominal or 240 volts nominal (autoranging).

Output Voltages:

Switcher Frame: +5.0V, –5.2V, +13.0V, –13.0, and +48V
Control Panel: +5V and +14V