2-3

Pre-installation Procedures

Physical Specifications and Installation Requirements
Physical dimensions for the Model 2200, shown in Table 2-1, are provided
to assist you in the installation.
* Allow 14 rack units total under switcher frame if installing redundant Power Supply.

Power Requirements

Power requirements for the Model 2200 control panel and switcher frame
are listed in Table 1-1 on page 1-11. The frame operates on 220 VAC only,
the control panel power supply is autoranging between 110 and 220 VAC.

Environmental Requirements

The Model 2200 has been designed to operate properly in environments
outlined in Table 1-7 on page 1-14.

Safety Requirements

The following precautions are provided to ensure that safety
considerations for both equipment and personnel are presented before any
installation procedures are begun. To prevent injury or equipment
damage, read, understand, and follow all installation safety precautions.
Table 2-1. Model 2200 Component Size Summary
Component Depth Width Height # of Rack
Units Weight
2200 Control Panel 23.5 inches
(578 mm) 47.0 inches
(1.194 M) 13.8 inches
(350 mm) n/a 150 lbs
(67 kgs)
Switcher Frame 22.5 inches
(571.5 mm) Std (19 inches)
(483 mm) 26.25 inches
(666.7 mm) 15 175 lbs
(78 kgs)
Power Supply 22.5 inches
(571.5 mm) Std (19 inches)
(483 mm) 12.25 inches
(311.1 mm) 7* 143 lbs
(65 kgs)