326X Series Modem Troubleshooting Guide (Continued)

Problem

Diagnosis/Test

Possible Solution

Cannot hear connection Check Speaker (ATM) option.

If the speaker is not on, turn it on.

through the speaker

 

 

(stand-alone units)

 

 

 

Check Volume (ATL) option.

Adjust volume.

 

 

 

DATA MODE

The modem connects, Check that the modem is in data

but cannot pass data mode (“Data 9600”, for example, displays).

Check that the TD LED is lit on modem's front panel (steady or flashing) indicating that the modem is receiving data from the DTE.

If the modem is not in data mode, establish a connection with the remote modem.

Check DTE for EIA signal requirements.

Ensure the modem is correctly cabled to the DTE (with a straight-through cable for your electrical interface—V.35 or RS-232).

Check that the correct communications port is being used.

Check the DTE rate of the local modem.

Check the DTE's flow control method.

If in normal mode, check for modem-to-modem flow control.

Verify line quality:

Ensure that the DTE rate matches the modem’s terminal rate setting.

Ensure that the DTE's flow control is the same as the modem’s setting

(for example, XON-XOFF, RTS/CTS).

If your communications software package’s file transfer protocol is used, and the package supports RTS/CTS Flow control, set Flow=RTS/CTS

(AT*FL3). If the package does not support RTS/ CTS flow control, set Flow=Off (AT*FL0).

Turn modem flow control off.

Troubleshooting

 

Run a remote digital

After running the RDL, if no errors occur, your line is

 

 

loopback (RDL) or RDL

good.

 

 

with pattern test.

If errors occur, perform a manual retrain, or retry the

 

 

 

 

 

 

phone call.

 

If you are still receiving

If the LAL or LAL with pattern test fails, contact Telenet-

 

 

errors, disconnect the

ics Customer Support or your local distributor.

 

 

modem from the line and

If the LAL or LAL with pattern test passes, you may have

 

 

perform a local analog

 

 

a line problem (contact your telephone company) or a

 

 

loopback (LAL) or LAL

 

 

problem with your application (check with your software

 

 

with pattern test (with

 

 

vendor).

 

 

modem flow control off).

 

 

 

 

 

 

Premature disconnect

Ensure that the remote modem

If the remote modem does not support error correction,

 

supports error correction.

set the modem to normal mode and retry the call.

 

Check the disconnect reason

Based upon the disconnect reason, take the appropriate

 

from the modem's front panel.

action.

 

 

 

 

Troubleshooting Guide 6-5

Page 109
Image 109
Telenetics 326X V.34, V.34-SDC, V.32bis Series manual Data Mode

326X V.34, V.32bis Series, V.34-SDC specifications

Telenetics has been a key player in the field of telecommunications, offering advanced modem solutions that cater to diverse communication needs. Among their notable products are the V.34-SDC and V.32bis series, including the 326X V.34 modem. These modems have been designed to enhance data transmission reliability and speed in various applications.

The Telenetics V.34-SDC modem represents a significant leap in technology, supporting data rates of up to 28.8 Kbps. This modem utilizes the advanced V.34 modulation scheme, which optimizes the use of existing telephone lines to deliver impressive performance, especially for users requiring high-speed data transmission. The V.34-SDC model also features robust error correction and data compression techniques, ensuring that users receive accurate data even over less than ideal connections. With its extended line-conditioning capabilities, the V.34-SDC modem can efficiently handle long distances and poor line conditions.

Equally noteworthy is the V.32bis series, which provides backward compatibility with V.32 modems, enabling seamless integration into existing systems. Capable of speeds up to 14.4 Kbps, the V.32bis modems are ideal for businesses and environments where legacy systems remain in use. It features adaptive equalization and advanced echo cancellation, ensuring a clear signal is maintained throughout the data transmission process. This versatility allows users to connect with various devices across different infrastructures.

The 326X V.34 modem further exemplifies Telenetics' commitment to high performance. It combines the V.34 capabilities with enhanced security features, offering users encryption options for sensitive data. This is particularly crucial for businesses that need to safeguard their information against potential vulnerabilities during transmission. The 326X also supports various data communication protocols, making it adaptable for multiple platforms and applications.

In summary, Telenetics’ V.34-SDC, V.32bis series, and 326X V.34 modems stand out for their high-speed data transmission, compatibility, advanced error correction, and security features. These technologies make them excellent choices for both enterprise and networking applications where reliable communication is vital. Telenetics continues to innovate, delivering modem solutions that meet the evolving demands of the telecommunications landscape.