Quick-Reference

Configuration

Table A-1.

AT Commands, Cross-Referenced to Front Panel Options (Continued)

AT

Parameter &

 

 

 

Command

Option

Description

 

 

 

 

 

AT*OP4

=2H/1L

 

 

 

AT*OP5

=2H/3L

 

 

 

AT*OP6

=2H/4L

 

 

 

AT*OP7

=3H/1L

 

 

 

AT*OP8

=3H/2L

 

 

 

AT*OP9

=3H/4L

 

 

 

AT*OP10

=4H/1L

 

 

 

AT*OP11

=4H/2L

 

 

 

AT*OP12

=4H/3L

 

 

 

 

Overspeed

Overspeed

 

 

Lets modem compensate when an async DTE sends data to the modem faster than specified .

AT*OS0

=1%

The modem compensates for DTE overspeed up to 1.0%.

AT*OS1

=2.5%

The modem compensates for DTE overspeed up to 2.5%.

 

Password

Enable/Disable Password Protection

 

 

Enables and disables the Password function. Once you have enabled the Password function, set

AT*PE0

 

protection in order to lock the modem (seeAT *PF).

=Disable

Disables the Password function.

AT*PE1

=Enable

Enables the Password function.

AT*PF

Set Protection

Lets you set protection to lock the modem. Refer to AT*PN for details.

AT*PN

Unlock Pass-

If you know your password, to unlock a password-protected modem and gain access to all

 

word Protection

modem functions, use the AT*PNxxxx command (where xxxx is the password).

 

 

If you forget your password, you can regain access to all modem functions by performing the

 

 

following procedure.

 

 

IMPORTANT: When you unlock a modem with this procedure, option settings and

 

 

telephone numbers are deleted from modem memory. Before using the modem again,

 

 

reconfigure option settings and re-enter stored telephone numbers.

 

 

1)Close Switch 4 on the rear panel (set it to down position). SeeTabl eA-6for details.

 

 

2)In the Status/Option Sets/Dialing menu, press

 

until Reinit Memory? displays

 

 

 

 

 

3)When you press , the modem displays Reinit All Mem?

 

 

4)Press again. The modem displays 326x Initial

 

 

5)The modem is now reset to factory default settings and all electronic telephone book entries

 

 

are deleted. Password protection is disabled and the password is set to 0000.

 

 

6)To use the password protection feature again, open Switch 4 on the modem rear panel (set it

 

 

to up position).

 

 

 

 

 

 

Dial

Dial Type

AT*PT0

=Tone

The modem uses tone dialing unless otherwise specified by the T or P dial modifiers in a

 

 

telephone number.

AT*PTl

=Pulse

The modem uses pulse dialing unless otherwise specified by the T or P dial modifiers in a

 

 

telephone number.

Gray shading indicates country-specific options. See Appendix C for your country’s options.

A-26 Configuration Quick Reference

Page 142
Image 142
Telenetics 326X V.34, V.34-SDC, V.32bis Series manual Overspeed, Password, Set Protection, Unlock Pass, Word Protection

326X V.34, V.32bis Series, V.34-SDC specifications

Telenetics has been a key player in the field of telecommunications, offering advanced modem solutions that cater to diverse communication needs. Among their notable products are the V.34-SDC and V.32bis series, including the 326X V.34 modem. These modems have been designed to enhance data transmission reliability and speed in various applications.

The Telenetics V.34-SDC modem represents a significant leap in technology, supporting data rates of up to 28.8 Kbps. This modem utilizes the advanced V.34 modulation scheme, which optimizes the use of existing telephone lines to deliver impressive performance, especially for users requiring high-speed data transmission. The V.34-SDC model also features robust error correction and data compression techniques, ensuring that users receive accurate data even over less than ideal connections. With its extended line-conditioning capabilities, the V.34-SDC modem can efficiently handle long distances and poor line conditions.

Equally noteworthy is the V.32bis series, which provides backward compatibility with V.32 modems, enabling seamless integration into existing systems. Capable of speeds up to 14.4 Kbps, the V.32bis modems are ideal for businesses and environments where legacy systems remain in use. It features adaptive equalization and advanced echo cancellation, ensuring a clear signal is maintained throughout the data transmission process. This versatility allows users to connect with various devices across different infrastructures.

The 326X V.34 modem further exemplifies Telenetics' commitment to high performance. It combines the V.34 capabilities with enhanced security features, offering users encryption options for sensitive data. This is particularly crucial for businesses that need to safeguard their information against potential vulnerabilities during transmission. The 326X also supports various data communication protocols, making it adaptable for multiple platforms and applications.

In summary, Telenetics’ V.34-SDC, V.32bis series, and 326X V.34 modems stand out for their high-speed data transmission, compatibility, advanced error correction, and security features. These technologies make them excellent choices for both enterprise and networking applications where reliable communication is vital. Telenetics continues to innovate, delivering modem solutions that meet the evolving demands of the telecommunications landscape.