Table A-1.

AT Commands, Cross-Referenced to Front Panel Options (Continued)

AT

Parameter &

 

Command

Option

Description

 

 

 

AT&W2

=2

Save changes to Option Set 2.

AT&W3

=3

Save changes to Option Set 3.

AT&W4

=4

Save changes to Option Set 4.

 

 

 

 

Clock

Clock

 

 

Sets modem timing and applies to synchronous applications only. For most dial applications,

 

 

use internal timing.

AT&X0

=Internal

The modem uses internal timing; timing signals are passed on EIA/TIA 232-D Pin 15(V.24

 

 

circuit 114). Internal timing is used for most applications.

AT&X1

=External

The modem uses external timing; timing signals are passed on EIA/TIA 232-D Pin 24 (V.24

 

 

circuit 113). Internal timing is used for most applications.

AT&X2

=Loopback

The modem uses loopback timing; timing signals are passed on EIA/TIA 232-D Pin 17 (V.24

 

 

circuit 115). NOTE: This selection is not available in SDC mode. If you select loopback with

 

 

SDC mode enabled, the modem uses internal timing instead.

 

 

 

 

Power Up In

Power Up In Option Set

AT&Y0

=Old

When you turn on the modem, it automatically uses the last saved option set.

AT&Y1

=1

When you turn on the modem, it automatically uses Option Set 1.

AT&Y2

=2

When you turn on the modem, it automatically uses Option Set 2.

AT&Y3

=3

When you turn on the modem, it automatically uses Option Set 3.

AT&Y4

=4

When you turn on the modem, it automatically uses Option Set 4.

 

 

 

 

Enter Phone #

Enter Telephone Numbers (where n=1-9)

AT&Zn

=1–9

Lets you store up to nine telephone numbers in the modem’s “address book” of up to 50

 

 

characters each. To enter a number into the address book: enter the AT&Z or AT*CN

 

 

command, the telephone book address (1-9), a comma, and the telephone number to store. For

 

 

example, to store the number 1-222-555-444 in memory location 3, enter:

 

 

AT*CN3,12225554444<CR>

 

 

If you enter AT&Z or AT*CN without specifying a memory location, the modem stores the

 

 

number in address 1. If no telephone number follows AT&Z or AT*CN, the specified memory

 

 

location’s telephone number is deleted. NOTE: When dialing telephone numbers, you can

 

 

include dial modifiers to instruct the modem how and when to dial a call. Refer to Table A-4.

 

 

 

 

Answer

Answer

AT*AA0

=Manual

An incoming call must be answered manually.

AT*AAl

Answer=Ring #

The modem automatically answers an incoming call after the first ring.

 

1

 

AT*AA2

=Ring # 2

The modem automatically answers an incoming call after the second ring.

 

 

AT*AA3

=Ring # 4

The modem automatically answers an incoming call after the fourth ring.

AT*AA4

=Ring # 8

The modem automatically answers an incoming call after the eighth ring.

AT*AA5

=Using S0

The modem automatically answers an incoming call according to the setting of S-Register S0.

 

Adaptive Rate

Adaptive Rate Feature

AT*AP0

=Off

The modem does not use the adaptive rate feature.

Gray shading indicates country-specific options. See Appendix C for your country’s options.

Configuration

Quick-Reference

Configuration Quick Reference A-13

Page 129
Image 129
Telenetics V.34-SDC, 326X V.34, V.32bis Series manual Clock, Power Up, Enter Phone #, Answer, Adaptive Rate

326X V.34, V.32bis Series, V.34-SDC specifications

Telenetics has been a key player in the field of telecommunications, offering advanced modem solutions that cater to diverse communication needs. Among their notable products are the V.34-SDC and V.32bis series, including the 326X V.34 modem. These modems have been designed to enhance data transmission reliability and speed in various applications.

The Telenetics V.34-SDC modem represents a significant leap in technology, supporting data rates of up to 28.8 Kbps. This modem utilizes the advanced V.34 modulation scheme, which optimizes the use of existing telephone lines to deliver impressive performance, especially for users requiring high-speed data transmission. The V.34-SDC model also features robust error correction and data compression techniques, ensuring that users receive accurate data even over less than ideal connections. With its extended line-conditioning capabilities, the V.34-SDC modem can efficiently handle long distances and poor line conditions.

Equally noteworthy is the V.32bis series, which provides backward compatibility with V.32 modems, enabling seamless integration into existing systems. Capable of speeds up to 14.4 Kbps, the V.32bis modems are ideal for businesses and environments where legacy systems remain in use. It features adaptive equalization and advanced echo cancellation, ensuring a clear signal is maintained throughout the data transmission process. This versatility allows users to connect with various devices across different infrastructures.

The 326X V.34 modem further exemplifies Telenetics' commitment to high performance. It combines the V.34 capabilities with enhanced security features, offering users encryption options for sensitive data. This is particularly crucial for businesses that need to safeguard their information against potential vulnerabilities during transmission. The 326X also supports various data communication protocols, making it adaptable for multiple platforms and applications.

In summary, Telenetics’ V.34-SDC, V.32bis series, and 326X V.34 modems stand out for their high-speed data transmission, compatibility, advanced error correction, and security features. These technologies make them excellent choices for both enterprise and networking applications where reliable communication is vital. Telenetics continues to innovate, delivering modem solutions that meet the evolving demands of the telecommunications landscape.