Table A-1.

AT Commands, Cross-Referenced to Front Panel Options (Continued)

AT

Parameter &

 

Command

Option

Description

 

 

 

AT*FL5

=TxClk

Transmit Clock. This option applies only in SDC mode. When the Tx Clk flow control option

 

 

is selected, the modem uses a transmit clock for flow control based on available buffer space.

 

 

The transmit clock is stopped when the buffers are full, inhibiting the flow of data from the

 

 

DTE. It is started again when buffer space is available. NOTE: This option is operational only

 

 

when internal timing has been selected (Clock=Internal, AT&X).

 

 

 

 

Hold DL Line

Hold Dial Line

 

 

This command forces the modem to hold a dial restoral connection while testing a leased line

 

 

connection. This command applies to modems configured for restoral.

AT*HD0

=Off

The Hold Dialine option is disabled; a dial modem configured for restoral disconnects from the

 

 

dial line normally. A leased line modem configured for restoral disconnects from the dial line

 

 

as soon as it connects to the leased line.

AT*HD1

=1min

A dial modem configured for restoral holds the dial line for 1 minute. A leased line modem

 

 

configured for restoral holds the dial line for 1 minute while testing the leased line.

AT*HD2

=2min

 

AT*HD3

=3min

 

AT*HD4

=4min

 

AT*HD5

=5min

 

 

DTE Ct. 141

DTE Circuit 141

 

 

Controls whether the local DTE can send the modem into a local analog loopback by sending a

 

 

signal on V.24 Circuit 141 (Pin 18) to the modem. The DTE must support Circuit 141 in order

 

 

to use this option.

AT*LA0

=Off

The modem does not respond to a signal on Circuit 141 (Pin 18).

AT*LAl

=On

An off-to-on transition on Circuit 141 (Pin 18) causes the modem to initiate a local analog

 

 

loopback test.

 

 

An on-to-off transition onV.24 Circuit 141 (Pin 18) takes the modem out of a local analog

 

 

loopback test.

 

 

 

 

Line Compen

Line Compensation

 

 

Enables the modem to compensate for the effects of low loss in the End Office-to-End Office

 

 

connections.

AT*LC0

=Off

Disables the Line Compensation option.

AT*LC1

=On

Enables the Line Compensation option.

 

DTE Ct. 140

DTE Circuit 140

 

 

Controls whether the local DTE can put the modem into a remote digital loopback by sending a

 

 

signal on V.24 Circuit 140 (Pin 21) to the modem.

AT*LD0

=Off

The modem does not respond to a signal on V.24 Circuit 140 (Pin 21).

AT*LDl

=On

An off-to-on transition onV.24 Circuit 140 (Pin 21) sends the modem into a remote digital

 

 

loopback test. An on-to-off transition on V.24 Circuit 140 (Pin 21) takes the modem out of a

 

 

remote digital loopback test.

 

 

 

 

D to L

Dial to Leased Option, Automatic Disconnect

 

 

Lets the modem automatically disconnect from the dial line and return to the leased line after a

 

 

specified period.

AT*LE0

=Manual

Pressing the Talk/Data key (at the Home position) returns the modem to the leased line.

Gray shading indicates country-specific options. See Appendix C for your country’s options.

Configuration

Quick-Reference

Configuration Quick Reference A-21

Page 137
Image 137
Telenetics V.32bis Series, V.34-SDC, 326X V.34 manual Hold DL Line, DTE Ct, Line Compen, To L

326X V.34, V.32bis Series, V.34-SDC specifications

Telenetics has been a key player in the field of telecommunications, offering advanced modem solutions that cater to diverse communication needs. Among their notable products are the V.34-SDC and V.32bis series, including the 326X V.34 modem. These modems have been designed to enhance data transmission reliability and speed in various applications.

The Telenetics V.34-SDC modem represents a significant leap in technology, supporting data rates of up to 28.8 Kbps. This modem utilizes the advanced V.34 modulation scheme, which optimizes the use of existing telephone lines to deliver impressive performance, especially for users requiring high-speed data transmission. The V.34-SDC model also features robust error correction and data compression techniques, ensuring that users receive accurate data even over less than ideal connections. With its extended line-conditioning capabilities, the V.34-SDC modem can efficiently handle long distances and poor line conditions.

Equally noteworthy is the V.32bis series, which provides backward compatibility with V.32 modems, enabling seamless integration into existing systems. Capable of speeds up to 14.4 Kbps, the V.32bis modems are ideal for businesses and environments where legacy systems remain in use. It features adaptive equalization and advanced echo cancellation, ensuring a clear signal is maintained throughout the data transmission process. This versatility allows users to connect with various devices across different infrastructures.

The 326X V.34 modem further exemplifies Telenetics' commitment to high performance. It combines the V.34 capabilities with enhanced security features, offering users encryption options for sensitive data. This is particularly crucial for businesses that need to safeguard their information against potential vulnerabilities during transmission. The 326X also supports various data communication protocols, making it adaptable for multiple platforms and applications.

In summary, Telenetics’ V.34-SDC, V.32bis series, and 326X V.34 modems stand out for their high-speed data transmission, compatibility, advanced error correction, and security features. These technologies make them excellent choices for both enterprise and networking applications where reliable communication is vital. Telenetics continues to innovate, delivering modem solutions that meet the evolving demands of the telecommunications landscape.