Watson & Sons 520DUN Good pump installation practice, General recommendations, Do’s and do not’s

Models: 520DUN

1 105
Download 105 pages 14.92 Kb
Page 16
Image 16

9 Good pump installation practice

9.1 General recommendations

A correctly engineered installation will promote long tube life. Site the pump on a flat, horizontal, rigid surface, free from excessive vibration, to ensure correct lubri- cation of the gearbox. Allow a free flow of air around the pump to ensure that heat can be dissipated. Ensure that the ambient temperature around the pump does not exceed 40C.

The STOP key on the keypad will always stop the pump. However, it is recommend- ed that a suitable local emergency stop device is fitted into the mains supply to the pump.

Do not stack pumps more than three high. When pumps are stacked, ensure that the ambient temperature around all the pumps in the stack does not exceed 40C.

The pump may be set up so that the direction of rotor rotation is clockwise or count- er-clockwise, whichever is convenient. Please note, however, that for the 520R and 501RL pumpheads tube life will be greater if the rotor rotates clockwise; and that performance against pressure will be maximised if the rotor rotates counter-clock- wise. To achieve 4 bar and 7 bar pressures using a 520RE pump and the appropri- ate rotor and element, the pump must rotate counter-clockwise.

Peristaltic pumps are self-priming and self-sealing against backflow. No valves are required in inlet or discharge lines, except as described below. Valves in the process flow must be opened before the pump operates. Users are advised to fit a pressure relief device between the pump and any valve on the discharge side of the pump to protect against damage caused by accidental operation with the discharge valve closed. Users of 520RE pumps at pressures up to 4 bar and 7 bar are advised to fit a non-return valve between the pump and the discharge pipework to avoid the sud- den release of pressurised fluid in the unlikely event of element failure.

9.2 Do’s and do not’s

Do not build a pump into a tight location without adequate airflow around the pump.

Do ensure that when the 520N watertight module is fitted the seals are intact and properly located.

Do ensure that the holes for cable glands are properly sealed to maintain theIP66 / NEMA 4X rating.

Watson-Marlow 520DuN IP66/NEMA 4X User Manual

16

Page 16
Image 16
Watson & Sons 520DUN user manual Good pump installation practice, General recommendations, Do’s and do not’s

520DUN specifications

Watson & Sons 520DUN is a state-of-the-art model that has garnered attention for its exceptional performance and innovative technologies. Designed for agricultural applications, this machine combines durability, efficiency, and ease of use, catering to the needs of modern farmers.

One of the standout features of the 520DUN is its robust engine. Equipped with a high-performance diesel engine, it offers impressive horsepower, allowing it to handle a variety of demanding tasks with ease. This engine is designed for fuel efficiency, ensuring that operators can complete their work without frequent refueling. The powertrain is complemented by an advanced transmission system that enables smooth gear shifts, enhancing operator comfort during long hours of operation.

The 520DUN also boasts a remarkable load capacity, making it an ideal choice for transporting heavy materials. Its rugged build quality ensures that it can withstand the rigors of daily use, providing a reliable solution for farmers and contractors alike. The robust chassis and reinforced components were designed to maintain stability and control, especially when navigating uneven terrain.

Incorporating cutting-edge technologies, the Watson & Sons 520DUN features precision farming capabilities. With GPS integration, operators can efficiently manage their fields, optimizing planting and harvesting processes. This technology not only increases yield but also minimizes inputs, making farming more sustainable and economically viable.

User ergonomics were a significant consideration in the design of the 520DUN. The operator's cabin is spacious and well-equipped with intuitive controls, providing a comfortable working environment. Operators will appreciate the advanced display panel that offers real-time data on performance metrics, fuel consumption, and maintenance reminders. This allows users to keep the machine in peak condition and react to any issues promptly.

Safety is also paramount in the design of the 520DUN. It features reinforced safety measures, including roll-over protection systems and visibility enhancements, ensuring operator safety during operations.

In summary, the Watson & Sons 520DUN represents the pinnacle of agricultural machinery with its powerful engine, remarkable load capacity, precision technology, and ergonomic design. It is tailored for those who seek reliability and efficiency in their agricultural endeavors, making it a noteworthy choice in today's competitive market.