Watson & Sons 520DUN user manual Pump specifications

Models: 520DUN

1 105
Download 105 pages 14.92 Kb
Page 13
Image 13

Pump specifications

Control range (turndown ratio)

0.1-360rpm (3,600:1)

Supply voltage/frequency

100-120V/200-240V 50/60Hz 1ph

 

±10% of nominal voltage.

Maximum voltage fluctuation

A well regulated electrical mains supply

is required along with cable connections

 

 

to the best practice of noise immunity

Installation category

II

(overvoltage category)

 

Power consumption

135VA

Full load current

<0.6A at 230V; <1.25A at 115V

Eprom version

Accessible through pump software

Enclosure rating

IP66 to BS EN 60529;

NEMA 4X to NEMA 250 *

 

Pumphead options

520R, 501RL, 313, 314, 505L,

505BA, 505CA, 314MC, 318MC

 

Operating temperature range

5C to 40C, 41F to 104F

Storage temperature range

-40C to 70C, -40F to 158F

Maximum altitude

2,000m, 6,560ft

Humidity (non-condensing)

80% up to 31C, 88F, decreasing linearly

to 50% at 40C, 104F

 

Pollution degree

2

 

 

* Protect from prolonged UV exposure.

Note: 520 drive models are C ETL US listed. Cert to std CAN/CSA C22.2 No 1010- 92. Conforms to std UL 61010A-1 April 30, 2002.

Note: 520 drive models have been tested in accordance with BS EN 61000-6-2:

2001 (EN 61000-4-4) Fast Transient and Burst Tests to Industrial limits – ie: Level 3: 2kV.

Watson-Marlow 520DuN IP66/NEMA 4X User Manual

13

Page 13
Image 13
Watson & Sons 520DUN user manual Pump specifications