18.10 Outputs
The 520DuN pump offers four relay status outputs. See 12 Switching the pump on for the first time for initial startup defaults. Each of five parameters can be config- ured to any output, or more than one output.
The parameters are:
Run / stop
Provides a status output to indicate whether the pumphead is in a running or stopped condition. When running at 0rpm, the run / stop output indicates run- ning.
Direction
Provides a status output to indicate which direction the pump is set to run in.
Auto / man
Provides a status output to indicate whether the pump is in analogue control mode or manual control mode.
General alarm
Provides an alarm output when any system error condition occurs except: leak detected; analogue signal out of range; analogue
Leak detected
When used with a leak detector, this output provides an alarm when the pump has been automatically switched off following tube failure.
Outputs
Note: The maximum rating on the relay contacts of this pump is 30VDC; maximum load 30W.
46 |