![](/images/new-backgrounds/1055642/55642161x1.webp)
28.1Pumphead position, removal and replacement
Always isolate the pump from the mains power sup- ply before opening the guard or performing any posi- tioning, removal or maintenance activity.
The pumphead track can be fitted in one of three orientations to provide right, up or down input/output port positions, whichever is convenient. Position the pump- head so that the tube ports face up or down only where the drive is placed on the bench edge - otherwise the pump tube or the hinged guard will impact the bench. Do not position the pumphead so that the tube ports face the keypad. Doing so may result in a safety risk.
The pump can be configured for clockwise or
To reposition the track
Open the pumphead guard as described under 27.1 Opening the pumphead guard, below.
Remove the rotor as described under Rotor removal, below.
Undo and withdraw the four
Remove the track.
Relocate the track in the desired position. Replace and tighten the
Replace the rotor as described under Rotor replacement below.
Close the guard, pushing it fully home until the latch engages.
81 |