www.ti.com

Test Setup

4.2.4Soft-Start Voltage Monitoring – TP1, TP2, and TP3

TPS53125EVM-599 provides two test points for measuring the soft-start ramp voltages. TP1 monitors the soft-start ramp of Channel 1. TP2 monitors the soft-start ramp of Channel 2. To use TP1 or TP2, connect an oscilloscope probe between TP1 or TP2 and TP3.

4.2.5Switching Node Monitoring – TP3, TP5, and TP11

TPS53125EVM-599 provides two test points for measuring the switching node waveform voltages. TP5 monitors the switching node of Channel 1. TP2 monitors the switching node of Channel 2. To use TP5 or TP11, connect an oscilloscope probe between TP5 or TP11 and TP3

4.2.65-V Regulator Output Monitoring – TP3 and TP10

TPS53125EVM-599 provides a test point for measuring the output of the internal 5-V regulator. TP10 monitors the output voltage of the internal 5-V regulator. To use TP10, connect a voltmeter positive terminal to TP10 and negative terminal to TP3.

5 Test Setup

5.1Equipment

The following equipment is recommended for testing the TPS53125EVM-599 evaluation board.

5.1.1Voltage Source

The input voltage source, VVIN, must be a 0-V to 15-V, variable dc source capable of supplying 3 Adc minimum.

5.1.2Meters

A1: 0-Adc to 4-Adc ammeter

V1: VIN, 0-V to 22-V voltmeter

V2: VOUT1, 0-V to 2-V voltmeter

V3: VOUT2, 0-V to 2-V voltmeter

5.1.3Loads

LOAD1: One output load is an electronic load set for constant current mode capable of 0 Adc to 4 Adc at 1.05 Vdc.

LOAD2: The other output load is an electronic load set for constant current mode capable of 0 Adc to 4 Adc at 1.8 Vdc.

5.1.4Oscilloscope and Probe

The oscilloscope, analog or digital, must be set for ac-coupled measurement with a 20-MHz bandwidth limiting. Use 20 mV/division vertical resolution, 1.0 µs/division horizontal resolution for the Output Ripple Voltage Test. Set cursors at +20 mV and –20 mV.

The oscilloscope probe must be a Tektronix P6138 or equivalent oscilloscope probe with exposed conductive ground barrels.

5.1.5Recommended Wire Gauge

VVIN to J3 – The connection between the source voltage, VVIN and J1 of TPS53125EVM-599 can carry as much as 2 Adc. The minimum recommended wire size is AWG #16 with the total length of wire less than 2

feet (1-foot input, 1-foot return).

SLVU392 –July 2010

TPS53125EVM-599

5

Copyright © 2010, Texas Instruments Incorporated

Page 5
Image 5
Texas Instruments TPS53125EVM-599 specifications Test Setup, Equipment